A Timing Complementary 2T1R Analog Content-Addressable Memory Design for Multimodal Medical Diagnosis

In the field of medical diagnosis, how to identify medical condition efficiently and give an accurate diagnosis on the edge is crucial for patient treatment. The memristor-based analog content-addressable memory (ACAM) emerges as a highly parallel accelerator for template matching technology. This study proposes a novel timing complementary 2T1R ACAM design for multimodal medical diagnosis that significantly reduces operational energy and area. The simulation results show that such design could achieve 2 ns matching speed and 34.2 fJ energy consumption per unit, while simultaneously reducing the area by 33% compared to the state-of-the-art design. Besides, a multimodal medical diagnosis task is demonstrated on a simulated ACAM array with a suitable configuration of design parameters.

Authors

Institutions

Publication Details

Published
2024-10-24
DOI
https://doi.org/10.1109/biocas61083.2024.10798298
Citations
1
Primary Topic
Brain Tumor Detection and Classification
Type
article
Field-Weighted Citation Impact
0.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Timing Complementary 2T1R Analog Content-Addressable Memory Design for Multimodal Medical Diagnosis

Yaotang Ji, Hui Xu, Zhiwei Li, Yinan Wang et al.
1 citations
Brain Tumor Detection and Classification
0.25
article

A Timing Complementary 2T1R Analog Content-Addressable Memory Design for Multimodal Medical Diagnosis

Yaotang Ji, Hui Xu, Zhiwei Li, Yinan Wang, Haijun Liu, Xinran Zhang, Haodong Hu, Qingjiang Li
article en
1 citations

Abstract

In the field of medical diagnosis, how to identify medical condition efficiently and give an accurate diagnosis on the edge is crucial for patient treatment. The memristor-based analog content-addressable memory (ACAM) emerges as a highly parallel accelerator for template matching technology. This study proposes a novel timing complementary 2T1R ACAM design for multimodal medical diagnosis that significantly reduces operational energy and area. The simulation results show that such design could achieve 2 ns matching speed and 34.2 fJ energy consumption per unit, while simultaneously reducing the area by 33% compared to the state-of-the-art design. Besides, a multimodal medical diagnosis task is demonstrated on a simulated ACAM array with a suitable configuration of design parameters.

National University of Defense Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Hunan Province
Openalex Percentile: Top 40%
Brain Tumor Detection and Classification
0.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.