K-Means Method for Clustering Groundwater Chemical Parameters of Konya Closed Basin

Cluster analysis, respectively K-Means method, is used to classify groundwater from Konya Closed Basin, located in Central Anatolia Region of Turkey. Datasets include the beginning (MB) and end (MS) of the season values for pH, Na and HCO3 spanning 2015–2022 period. There are 163 water wells (stations) in Konya Closed Basin where chemical properties were measured. Additionally, an EDA and statistical analysis was performed. The international standards for pH, Na and HCO3 in drinking water and irrigation water are generally respected. To evaluate the success of cluster separation using the K-Means technique, we estimated the silhouette coefficient. The results reveal that, generally, 2 to 4 clusters were determined for all models proposed. This approach can help to identify those wells that exceed the standard values of the investigated chemical parameters for drinking and irrigation water. In this way, the water management department could take improvement measures over time.

Authors

Institutions

Publication Details

Published
2024-11-04
DOI
https://doi.org/10.1109/iceccme62383.2024.10796675
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

K-Means Method for Clustering Groundwater Chemical Parameters of Konya Closed Basin

Vahdettin Demir, Carmen Elena Maftei, K. Kucuk, Radu Muntean et al.
Fault Detection and Control Systems
article

K-Means Method for Clustering Groundwater Chemical Parameters of Konya Closed Basin

Vahdettin Demir, Carmen Elena Maftei, K. Kucuk, Radu Muntean, Cristina Şerban
article en

Abstract

Cluster analysis, respectively K-Means method, is used to classify groundwater from Konya Closed Basin, located in Central Anatolia Region of Turkey. Datasets include the beginning (MB) and end (MS) of the season values for pH, Na and HCO3 spanning 2015–2022 period. There are 163 water wells (stations) in Konya Closed Basin where chemical properties were measured. Additionally, an EDA and statistical analysis was performed. The international standards for pH, Na and HCO3 in drinking water and irrigation water are generally respected. To evaluate the success of cluster separation using the K-Means technique, we estimated the silhouette coefficient. The results reveal that, generally, 2 to 4 clusters were determined for all models proposed. This approach can help to identify those wells that exceed the standard values of the investigated chemical parameters for drinking and irrigation water. In this way, the water management department could take improvement measures over time.

Ovidius University (RO), Transylvania University of Brașov (RO), KTO Karatay University (TR)
Universitatea Transilvania din Brasov
Clean water and sanitation
Openalex Percentile: Top 72%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.