Inherent stochasticity, noise and limits of detection in continuous and time-gated fluorescence systems

We present a model for the noise and inherent stochasticity of fluorescence signals in both continuous wave (CW) and time-gated (TG) conditions. When the fluorophores are subjected to an arbitrary excitation photon flux, we apply the model and compute the evolution of the probability mass function (pmf) for each quantum state comprising a fluorophore's electronic structure, and hence the dynamics of the resulting emission photon flux. Both the ensemble and stochastic models presented in this work have been verified using Monte Carlo molecular dynamic simulations that utilize the Gillespie algorithm. The implications of the model on the design of biomolecular fluorescence detection systems are explored in three relevant numerical examples. For a given system, the quantum-limited signal-to-noise ratio (QSNR) and limits of detection are computed to demonstrate how key design tradeoffs are quantified. We find that as systems scale down to micro- and nano- dimensions, the interplay between the fluorophore's photophysical qualities and use of CW or TG has ramifications on optimal design strategies when considering optical component selection, measurement speed, and system energy requirements. While CW systems remain a gold standard, TG systems can be leveraged to overcome cost and system complexity hurdles when paired with the appropriate fluorophore.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-12-23
DOI
https://doi.org/10.1371/journal.pone.0313949
Citations
1
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inherent stochasticity, noise and limits of detection in continuous and time-gated fluorescence systems

Boris Murmann, Nicholas Vitale, H. Tom Soh, Thomas H. Lee et al.
1 citations
PLoS ONE
Advanced Fluorescence Microscopy Techniques
0.66
article

Inherent stochasticity, noise and limits of detection in continuous and time-gated fluorescence systems

Boris Murmann, Nicholas Vitale, H. Tom Soh, Thomas H. Lee, Arjang Hassibi
article en
1 citations

Abstract

We present a model for the noise and inherent stochasticity of fluorescence signals in both continuous wave (CW) and time-gated (TG) conditions. When the fluorophores are subjected to an arbitrary excitation photon flux, we apply the model and compute the evolution of the probability mass function (pmf) for each quantum state comprising a fluorophore's electronic structure, and hence the dynamics of the resulting emission photon flux. Both the ensemble and stochastic models presented in this work have been verified using Monte Carlo molecular dynamic simulations that utilize the Gillespie algorithm. The implications of the model on the design of biomolecular fluorescence detection systems are explored in three relevant numerical examples. For a given system, the quantum-limited signal-to-noise ratio (QSNR) and limits of detection are computed to demonstrate how key design tradeoffs are quantified. We find that as systems scale down to micro- and nano- dimensions, the interplay between the fluorophore's photophysical qualities and use of CW or TG has ramifications on optimal design strategies when considering optical component selection, measurement speed, and system energy requirements. While CW systems remain a gold standard, TG systems can be leveraged to overcome cost and system complexity hurdles when paired with the appropriate fluorophore.

PLoS ONEVol. 19(12)
University of Hawaiʻi at Mānoa (US), Stanford University (US)
National Science Foundation, Samsung
Affordable and clean energy
Openalex Percentile: Top 18%
Advanced Fluorescence Microscopy Techniques
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Inherent stochasticity, noise and limits of detection in continuous and time-gated fluorescence systems — Boris Murmann, Nicholas Vitale, et al. · PLoS ONE (2024) | TGRS Research Map | TGRS