Comment on the Case Report of “A Miniscleral Contact Lens Fitting in a Patient of Unilateral Terrien’s Marginal Degeneration”

Dear Editor, I am writing to address some concerns regarding the dynamic fitting assessment described in the recent case report titled “A miniscleral contact lens fitting in a patient of unilateral Terrien’s marginal degeneration” author by Jain et al.[1] While the authors provide valuable insights into the management of corneal ectasia using miniscleral contact lenses, there are certain drawbacks in the dynamic and static fitting assessment methodology that warrant attention. The authors reported that the dynamic fitting assessment was conducted using fluorescein staining in cobalt blue filter of the slit lamp, revealing adequate edge lift with no perilimbal blanching of the vessels. However, it is crucial to note that while the static fitting assessment utilized fluorescence dye, the dynamic fitting assessment in contact lens was performed without fluorescein staining.[2] This discrepancy raises the concerns about the consistency and reliability of the dynamic fitting evaluation. Ensuring proper fit and comfort of contact lenses is crucial, especially for irregular corneas such as those in Terrien’s marginal degeneration cases. Fluorescein staining is a common technique used to evaluate contact lens alignment, edge lift, and overall fitting characteristics. This process, referred to as static fitting assessment, provides valuable insights into the interaction between the lens and the ocular surface, enhancing comfort and effectiveness. Thank you for considering these methodological concerns. I believe addressing these issues will contribute to the advancement of evidence-based practice in contact lens fitting and improve the quality of care for patients with corneal ectasia. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.

Authors

Publication Details

Journal
Delhi Journal of Ophthalmology
Published
2024-10-01
DOI
https://doi.org/10.4103/dljo.dljo_45_24
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comment on the Case Report of “A Miniscleral Contact Lens Fitting in a Patient of Unilateral Terrien’s Marginal Degeneration”

Suraj Kumar Chaurasiya
Delhi Journal of Ophthalmology
Ocular Surface and Contact Lens
article

Comment on the Case Report of “A Miniscleral Contact Lens Fitting in a Patient of Unilateral Terrien’s Marginal Degeneration”

Suraj Kumar Chaurasiya
article en

Abstract

Dear Editor, I am writing to address some concerns regarding the dynamic fitting assessment described in the recent case report titled “A miniscleral contact lens fitting in a patient of unilateral Terrien’s marginal degeneration” author by Jain et al.[1] While the authors provide valuable insights into the management of corneal ectasia using miniscleral contact lenses, there are certain drawbacks in the dynamic and static fitting assessment methodology that warrant attention. The authors reported that the dynamic fitting assessment was conducted using fluorescein staining in cobalt blue filter of the slit lamp, revealing adequate edge lift with no perilimbal blanching of the vessels. However, it is crucial to note that while the static fitting assessment utilized fluorescence dye, the dynamic fitting assessment in contact lens was performed without fluorescein staining.[2] This discrepancy raises the concerns about the consistency and reliability of the dynamic fitting evaluation. Ensuring proper fit and comfort of contact lenses is crucial, especially for irregular corneas such as those in Terrien’s marginal degeneration cases. Fluorescein staining is a common technique used to evaluate contact lens alignment, edge lift, and overall fitting characteristics. This process, referred to as static fitting assessment, provides valuable insights into the interaction between the lens and the ocular surface, enhancing comfort and effectiveness. Thank you for considering these methodological concerns. I believe addressing these issues will contribute to the advancement of evidence-based practice in contact lens fitting and improve the quality of care for patients with corneal ectasia. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.

Delhi Journal of OphthalmologyVol. 34(4)
Openalex Percentile: Top 63%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.