Restoration of AFM Images that were Produced using the Estimated AFM Tip at Three Different Scanning Speeds

The contact between the sample and the AFM tip causes distortions in all atomic force microscope (AFM) pictures. With the three-dimensional tip form in hand, the distorted picture may be straightened out and the surface structure's original state "restored" using deconvolution methods. Compared to the initial distorted image, the restored image provides a more realistic portrayal of the sample's true 3D surface. In order to estimate the impulse response of the AFM, this work presents a new method that uses contact mode AFM to measure the dimensions of a micro-cylinder. Subsequent AFM pictures are subsequently restored using the predicted impulse response.

Authors

Institutions

Publication Details

Journal
WSEAS TRANSACTIONS ON SIGNAL PROCESSING
Published
2024-12-23
DOI
https://doi.org/10.37394/232014.2024.20.10
Primary Topic
Force Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Restoration of AFM Images that were Produced using the Estimated AFM Tip at Three Different Scanning Speeds

Ahmed Ahtaiba
WSEAS TRANSACTIONS ON SIGNAL PROCESSING
Force Microscopy Techniques and Applications
article

Restoration of AFM Images that were Produced using the Estimated AFM Tip at Three Different Scanning Speeds

Ahmed Ahtaiba
article en

Abstract

The contact between the sample and the AFM tip causes distortions in all atomic force microscope (AFM) pictures. With the three-dimensional tip form in hand, the distorted picture may be straightened out and the surface structure's original state "restored" using deconvolution methods. Compared to the initial distorted image, the restored image provides a more realistic portrayal of the sample's true 3D surface. In order to estimate the impulse response of the AFM, this work presents a new method that uses contact mode AFM to measure the dimensions of a micro-cylinder. Subsequent AFM pictures are subsequently restored using the predicted impulse response.

WSEAS TRANSACTIONS ON SIGNAL PROCESSINGVol. 20
Sirte University (LY)
National Institute of Standards and Technology
Sustainable cities and communities
Openalex Percentile: Top 78%
Force Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.