Development of Pyramidal Microwells for Enhanced Cell Spheroid Formation in a Cell-on-Chip Microfluidic System for Cardiac Differentiation of Mouse Embryonic Stem Cells

Three-dimensional (3D) tissue culture models provide in vivo-like conditions for studying cell physiology. This study aimed to examine the efficiency of pyramidal microwell geometries in microfluidic devices on spheroid formation, cell growth, viability, and differentiation in mouse embryonic stem cells (mESCs). The static culture using the hanging drop (HD) method served as a control. The microfluidic chips were fabricated to have varying pyramidal tip angles, including 66°, 90°, and 106°. From flow simulations, when the tip angle increased, streamline distortion decreased, resulting in more uniform flow and a lower velocity gradient near the spheroids. These findings demonstrate the significant influence of microwell geometry on fluid dynamics. The 90° microwells provide optimal conditions, including uniform flow and reduced shear stress, while maintaining the ability for waste removal, resulting in superior spheroid growth compared to the HD method and other microwell designs. From the experiments, by Day 3, spheroids in the 90° microwells reached approximately 400 µm in diameter which was significantly larger than those in the 66° microwells, 106° microwells, and HD cultures. Brachyury gene expression in the 90° microwells was four times higher than the HD method, indicating enhanced mesodermal differentiation essential for cardiac differentiation. Immunofluorescence staining confirmed cardiomyocyte differentiation. In conclusion, microwell geometry significantly influences 3D cell culture outcomes. The pyramidal microwells with a 90° tip angle proved most effective in promoting spheroid growth and cardiac differentiation of mESC differentiation, providing insights for optimizing microfluidic systems in tissue engineering and regenerative medicine.

Authors

Institutions

Publication Details

Journal
Cells
Published
2024-12-23
DOI
https://doi.org/10.3390/cells13242132
Citations
4
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Pyramidal Microwells for Enhanced Cell Spheroid Formation in a Cell-on-Chip Microfluidic System for Cardiac Differentiation of Mouse Embryonic Stem Cells

Alongkorn Pimpin, Wirakan Kallayanathum, Kriengkrai Chessadangkul, Tepparit Wongpakham et al.
4 citations
Cells
3D Printing in Biomedical Research
0.74
article

Development of Pyramidal Microwells for Enhanced Cell Spheroid Formation in a Cell-on-Chip Microfluidic System for Cardiac Differentiation of Mouse Embryonic Stem Cells

Alongkorn Pimpin, Wirakan Kallayanathum, Kriengkrai Chessadangkul, Tepparit Wongpakham, Sudchaya Bhanpattanakul, Theerawat Tharasanit, Wutthinan Jeamsaksiri, Thanapat Chunfong
article en
4 citations

Abstract

Three-dimensional (3D) tissue culture models provide in vivo-like conditions for studying cell physiology. This study aimed to examine the efficiency of pyramidal microwell geometries in microfluidic devices on spheroid formation, cell growth, viability, and differentiation in mouse embryonic stem cells (mESCs). The static culture using the hanging drop (HD) method served as a control. The microfluidic chips were fabricated to have varying pyramidal tip angles, including 66°, 90°, and 106°. From flow simulations, when the tip angle increased, streamline distortion decreased, resulting in more uniform flow and a lower velocity gradient near the spheroids. These findings demonstrate the significant influence of microwell geometry on fluid dynamics. The 90° microwells provide optimal conditions, including uniform flow and reduced shear stress, while maintaining the ability for waste removal, resulting in superior spheroid growth compared to the HD method and other microwell designs. From the experiments, by Day 3, spheroids in the 90° microwells reached approximately 400 µm in diameter which was significantly larger than those in the 66° microwells, 106° microwells, and HD cultures. Brachyury gene expression in the 90° microwells was four times higher than the HD method, indicating enhanced mesodermal differentiation essential for cardiac differentiation. Immunofluorescence staining confirmed cardiomyocyte differentiation. In conclusion, microwell geometry significantly influences 3D cell culture outcomes. The pyramidal microwells with a 90° tip angle proved most effective in promoting spheroid growth and cardiac differentiation of mESC differentiation, providing insights for optimizing microfluidic systems in tissue engineering and regenerative medicine.

CellsVol. 13(24)
National Electronics and Computer Technology Center (TH), Chulalongkorn University (TH)
European Commission, Chulalongkorn University, Thailand Science Research and Innovation, Thailand Graduate Institute of Science and Technology
Clean water and sanitation
Openalex Percentile: Top 31%
3D Printing in Biomedical Research
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.