Workload Assessment of Operators: Correlation Between NASA-TLX and Pupillary Responses

Operators in high-stress environments often face significant cognitive demands that can impair their performance, underscoring the need for comprehensive workload assessment. This study aims to study the relationship between subjective self-reported measures, the NASA task load index (NASA-TLX), objective bio-signal measures, and pupillary responses. The participants engaged in either a visual tracking task or a laparoscopic visuomotor task while their eye movements were recorded using a Tobii Pro Nano eye tracker (Tobii Technology Inc., Stockholm, Sweden). Immediately after completing the tasks, participants provided NASA-TLX scores to assess their perceived workload. The study tested three hypotheses: first, whether increased pupil dilation correlates with higher NASA-TLX scores; second, whether task type affects workload; and third, whether task repetition influences workload. The results showed a moderate positive correlation between pupil size and NASA-TLX scores (r = 0.513, p < 0.001). The laparoscopic surgery task, which requires visuomotor coordination, resulted in significantly higher NASA-TLX scores (t = –6.23, p < 0.001), larger original pupil sizes (t = –22.57, p < 0.001), and more adjusted pupil sizes (t = –22.57, p < 0.001) than the purely visual task. Additionally, task repetition led to a significant reduction in the NASA-TLX scores (t = 2.86, p = 0.005), the original mean pupil size (t = 5.50, p < 0.001), and the adjusted pupil size (t = 6.34, p < 0.001). In conclusion, the study confirms a positive correlation between NASA-TLX scores and pupillary responses. Task type and repetition were found to influence workload and pupillary responses. The findings demonstrate the value of using both subjective and objective measures for workload assessments.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-12-20
DOI
https://doi.org/10.3390/app142411975
Citations
14
Primary Topic
Human-Automation Interaction and Safety
Type
article
Field-Weighted Citation Impact
9.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Workload Assessment of Operators: Correlation Between NASA-TLX and Pupillary Responses

Bin Zheng, Yao Zhang, Yun Wu
14 citations
Applied Sciences
Human-Automation Interaction and Safety
9.01
article

Workload Assessment of Operators: Correlation Between NASA-TLX and Pupillary Responses

Bin Zheng, Yao Zhang, Yun Wu
article en
14 citations

Abstract

Operators in high-stress environments often face significant cognitive demands that can impair their performance, underscoring the need for comprehensive workload assessment. This study aims to study the relationship between subjective self-reported measures, the NASA task load index (NASA-TLX), objective bio-signal measures, and pupillary responses. The participants engaged in either a visual tracking task or a laparoscopic visuomotor task while their eye movements were recorded using a Tobii Pro Nano eye tracker (Tobii Technology Inc., Stockholm, Sweden). Immediately after completing the tasks, participants provided NASA-TLX scores to assess their perceived workload. The study tested three hypotheses: first, whether increased pupil dilation correlates with higher NASA-TLX scores; second, whether task type affects workload; and third, whether task repetition influences workload. The results showed a moderate positive correlation between pupil size and NASA-TLX scores (r = 0.513, p < 0.001). The laparoscopic surgery task, which requires visuomotor coordination, resulted in significantly higher NASA-TLX scores (t = –6.23, p < 0.001), larger original pupil sizes (t = –22.57, p < 0.001), and more adjusted pupil sizes (t = –22.57, p < 0.001) than the purely visual task. Additionally, task repetition led to a significant reduction in the NASA-TLX scores (t = 2.86, p = 0.005), the original mean pupil size (t = 5.50, p < 0.001), and the adjusted pupil size (t = 6.34, p < 0.001). In conclusion, the study confirms a positive correlation between NASA-TLX scores and pupillary responses. Task type and repetition were found to influence workload and pupillary responses. The findings demonstrate the value of using both subjective and objective measures for workload assessments.

Applied SciencesVol. 14(24)
University of Alberta (CA)
China Scholarship Council
Openalex Percentile: Top 2%
Human-Automation Interaction and Safety
9.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.