Evaluating a Solar–Biogas Hybrid Renewable Power Plant by Heating the Anaerobic Digester Using the Rejected Heat of Rankine Cycle in Idlib, Syria

This research includes modeling and studying the performance improvement of a hybrid renewable energy power plant using the modeling software Greenius in Idlib, Syria. The system consists of solar parabolic trough collectors and an anaerobic digester for generating biogas. This study included a practical experiment for generating biogas using five identical digesters operating at five different temperatures. The raw material was a mixture of 81% food waste and 19% human waste, and average temperatures were as follows: 49.6, 45.9, 43.5, 37.5, and 33.2 °C. Modeling operations were conducted for each case, as well as for the case corresponding to the highest growth rate of methanogenic bacteria theoretically. The modeling processes were conducted at 11 different values for the storage capacity from Full Load Hours (FLHs) 0 to 10 and by varying the solar multiple factor (SM) from 1 to 8. This study showed that when operating as a net solar plant, the lowest value for the cost of produced electricity (LCOE) was 0.1785 EUR/kWh at FLHs = 5 h and SM = 2, while the annual electricity production was 25.21 GWh. The maximum annual electricity production was 48.66 GWh, achieved at FLHs = 10 h, SM = 8, and the LCOE = 0.2896 EUR/kWh. It is possible to obtain annual electrical energy of 39.7 GWh, which was about 82% of the maximum possible annual production, at a cost of LCOE = 0.1864 EUR/kWh, which is less than 5% higher than the lowest possible cost. When operating as a hybrid plant with an annual capacity factor of 1 (full load), it is discovered that the lowest value of energy produced is in the third scenario at tAD = 43.52 °C and tc = 63.5 °C, with FLHs = 0 h and SM = 1, with the LCOE = 0.1283 EUR/kWh.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-12-23
DOI
https://doi.org/10.3390/app142412027
Citations
2
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating a Solar–Biogas Hybrid Renewable Power Plant by Heating the Anaerobic Digester Using the Rejected Heat of Rankine Cycle in Idlib, Syria

Radwan A. Almasri, Ayman Abdul Karim Alhijazi, Ahmad Firas Alloush
2 citations
Applied Sciences
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
0.43
article

Evaluating a Solar–Biogas Hybrid Renewable Power Plant by Heating the Anaerobic Digester Using the Rejected Heat of Rankine Cycle in Idlib, Syria

Radwan A. Almasri, Ayman Abdul Karim Alhijazi, Ahmad Firas Alloush
article en
2 citations

Abstract

This research includes modeling and studying the performance improvement of a hybrid renewable energy power plant using the modeling software Greenius in Idlib, Syria. The system consists of solar parabolic trough collectors and an anaerobic digester for generating biogas. This study included a practical experiment for generating biogas using five identical digesters operating at five different temperatures. The raw material was a mixture of 81% food waste and 19% human waste, and average temperatures were as follows: 49.6, 45.9, 43.5, 37.5, and 33.2 °C. Modeling operations were conducted for each case, as well as for the case corresponding to the highest growth rate of methanogenic bacteria theoretically. The modeling processes were conducted at 11 different values for the storage capacity from Full Load Hours (FLHs) 0 to 10 and by varying the solar multiple factor (SM) from 1 to 8. This study showed that when operating as a net solar plant, the lowest value for the cost of produced electricity (LCOE) was 0.1785 EUR/kWh at FLHs = 5 h and SM = 2, while the annual electricity production was 25.21 GWh. The maximum annual electricity production was 48.66 GWh, achieved at FLHs = 10 h, SM = 8, and the LCOE = 0.2896 EUR/kWh. It is possible to obtain annual electrical energy of 39.7 GWh, which was about 82% of the maximum possible annual production, at a cost of LCOE = 0.1864 EUR/kWh, which is less than 5% higher than the lowest possible cost. When operating as a hybrid plant with an annual capacity factor of 1 (full load), it is discovered that the lowest value of energy produced is in the third scenario at tAD = 43.52 °C and tc = 63.5 °C, with FLHs = 0 h and SM = 1, with the LCOE = 0.1283 EUR/kWh.

Applied SciencesVol. 14(24)
Qassim University (SA), Idlib University
Qassim University
Responsible consumption and production
Openalex Percentile: Top 40%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.