A simulated ‘can’t intubate, can’t oxygenate’ manikin crossover study investigating a modified front-of-neck access airway device

A 'can't intubate, can't oxygenate' (CICO) situation is an uncommon and time-critical emergency. Many institutions have adopted a 'scalpel-bougie-endotracheal tube (ETT)' technique based on evidence produced by the 4th National Audit Project of the Royal College of Anaesthetists and 2015 Difficult Airway Society guidelines. We made a modification to the traditional 'scalpel-bougie-ETT' technique, using a shortened bougie and replacing the ETT with a cuffed Melker airway in a preassembled device (called 'Secure Airway for Front-of-neck Emergencies' (SAFE airway device)), which we felt might reduce cognitive load on a single operator in an emergency CICO situation. We then performed a simulation crossover study using 20 volunteer anaesthetic doctors to compare this modification with the traditional technique. After a standardised pre-recorded video demonstration, participants performed simulated tube insertion using both the standard 'scalpel-bougie-ETT' technique and the SAFE airway device in randomised order. Participants were filmed for accurate timestamping. The primary outcome was time to successful tube insertion while secondary outcomes included number of attempts and ease of insertion. Overall time to cuff inflation was shorter, statistically and practically, with the SAFE airway device compared with the ETT (median 30 <i>vs</i>. 52 seconds, <i>P</i> < 0.001). Twenty-five percent of participants required multiple attempts using the ETT method versus 5% using the SAFE airway device, which was also rated as being easier to use. This study demonstrates that the SAFE airway device was fast, effective, easy to use and acceptable to airway practitioners in a simulated manikin environment. These findings indicate that further studies of the SAFE airway device are warranted.

Authors

Institutions

Publication Details

Journal
Anaesthesia and Intensive Care
Published
2024-12-23
DOI
https://doi.org/10.1177/0310057x241266861
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A simulated ‘can’t intubate, can’t oxygenate’ manikin crossover study investigating a modified front-of-neck access airway device

Dharam P. Sharma, Adam Mahoney, Martha C. Anderson, Stuart Paterson et al.
Anaesthesia and Intensive Care
Airway Management and Intubation Techniques
article

A simulated ‘can’t intubate, can’t oxygenate’ manikin crossover study investigating a modified front-of-neck access airway device

Dharam P. Sharma, Adam Mahoney, Martha C. Anderson, Stuart Paterson, Zeik Devereaux-McLean, Georgia Mohler
article en

Abstract

A 'can't intubate, can't oxygenate' (CICO) situation is an uncommon and time-critical emergency. Many institutions have adopted a 'scalpel-bougie-endotracheal tube (ETT)' technique based on evidence produced by the 4th National Audit Project of the Royal College of Anaesthetists and 2015 Difficult Airway Society guidelines. We made a modification to the traditional 'scalpel-bougie-ETT' technique, using a shortened bougie and replacing the ETT with a cuffed Melker airway in a preassembled device (called 'Secure Airway for Front-of-neck Emergencies' (SAFE airway device)), which we felt might reduce cognitive load on a single operator in an emergency CICO situation. We then performed a simulation crossover study using 20 volunteer anaesthetic doctors to compare this modification with the traditional technique. After a standardised pre-recorded video demonstration, participants performed simulated tube insertion using both the standard 'scalpel-bougie-ETT' technique and the SAFE airway device in randomised order. Participants were filmed for accurate timestamping. The primary outcome was time to successful tube insertion while secondary outcomes included number of attempts and ease of insertion. Overall time to cuff inflation was shorter, statistically and practically, with the SAFE airway device compared with the ETT (median 30 <i>vs</i>. 52 seconds, <i>P</i> < 0.001). Twenty-five percent of participants required multiple attempts using the ETT method versus 5% using the SAFE airway device, which was also rated as being easier to use. This study demonstrates that the SAFE airway device was fast, effective, easy to use and acceptable to airway practitioners in a simulated manikin environment. These findings indicate that further studies of the SAFE airway device are warranted.

Anaesthesia and Intensive CareVol. 53(1)
University of Tasmania (AU), Launceston General Hospital (AU), North West Regional Hospital (AU), Royal Hobart Hospital (AU)
Openalex Percentile: Top 57%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.