PEMBERHENTIAN PENGECORAN BETON UNTUK PEKERJAAN KONSTRUKSI LENTUR BERDASARKAN SNI 2847-2019

The presence of construction joints is an inevitable aspect of field concrete casting. These joints occur when fresh concrete is poured over hardened concrete, which can impact the strength and integrity of the concrete structure. This study aims to evaluate the placement of concrete joints according to SNI 2847-2019, which recommends placing them at one-third of the span of the beam. Testing was conducted on unreinforced concrete beams with two different joint locations. The concrete used had a water-cement ratio (w/c) of 0.5 and a maximum aggregate size of 25 mm, with the mix design following SNI 7656-2012. The test results indicate that joints placed at one-third of the span exhibit better flexural strength compared to those located at the span's ends. The average flexural strengths of beams without joints, those with joints at one-third of the span, and those with joints at one-third of the end span are 1.95 MPa, 1.56 MPa, and 0.98 MPa, respectively. These findings support the SNI 2847-2019 recommendation for placing concrete joints at one-third of the span of the beam.

Authors

Institutions

Publication Details

Journal
Construction and Material Journal
Published
2024-12-23
DOI
https://doi.org/10.32722/cmj.v6i2.7294
Primary Topic
Geotechnical and construction materials studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PEMBERHENTIAN PENGECORAN BETON UNTUK PEKERJAAN KONSTRUKSI LENTUR BERDASARKAN SNI 2847-2019

Anni Susilowati, Pratikto Pratikto, Abdira Gym Wijaya
Construction and Material Journal
Geotechnical and construction materials studies
article

PEMBERHENTIAN PENGECORAN BETON UNTUK PEKERJAAN KONSTRUKSI LENTUR BERDASARKAN SNI 2847-2019

Anni Susilowati, Pratikto Pratikto, Abdira Gym Wijaya
article en

Abstract

The presence of construction joints is an inevitable aspect of field concrete casting. These joints occur when fresh concrete is poured over hardened concrete, which can impact the strength and integrity of the concrete structure. This study aims to evaluate the placement of concrete joints according to SNI 2847-2019, which recommends placing them at one-third of the span of the beam. Testing was conducted on unreinforced concrete beams with two different joint locations. The concrete used had a water-cement ratio (w/c) of 0.5 and a maximum aggregate size of 25 mm, with the mix design following SNI 7656-2012. The test results indicate that joints placed at one-third of the span exhibit better flexural strength compared to those located at the span's ends. The average flexural strengths of beams without joints, those with joints at one-third of the span, and those with joints at one-third of the end span are 1.95 MPa, 1.56 MPa, and 0.98 MPa, respectively. These findings support the SNI 2847-2019 recommendation for placing concrete joints at one-third of the span of the beam.

Construction and Material JournalVol. 6(2)
Jakarta State Polytechnic (ID)
Sustainable cities and communities
Openalex Percentile: Top 73%
Geotechnical and construction materials studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.