Sensitive and Fast Simultaneous Voltammetric Determination of Dopamine and Uric Acid Using Simple Screen‐Printed Carbon Electrode Without Pretreatment and Modification

A simple, commercially available, unmodified screen‐printed carbon electrode (SPCE) was investigated for the simultaneous voltammetric determination of dopamine (D/A) and uric acid (U/A) in a medium of very low concentration of supporting electrolyte for the first time. The ordinary, simple SPCE from DropSens (DS‐SPCE) was found to be able to separate the overlapping peaks of D/A and U/A with a wide peak potential separation of 300 mV in a medium of very low concentration (0.001 M) of NaH 2 PO 4 as supporting electrolyte (buffer of low capacity) at pH 8.0. Medium of low concentration of electrolyte made it possible to expose the bare electrode surface for its high catalytic activity which resulted into a high peak current signals, particularly for D/A. The DS‐SPCE showed excellent electrocatalytic performance than the other SPCE. The effect of electrolyte concentration and pH on the electrocatalytic behavior of electrode were thoroughly discussed. The DS‐SPCE displayed a sensitive results in good linear ranges from 0.1–5 to 6–20 µM for D/A and 0.5–41.5 µM for U/A. The disposable electrode demonstrated better discrimination ability toward the detection of D/A and U/A over ascorbic acid and other potential interfering species. Moreover, the sensor presented sensitive and highly accurate results in human urine samples without preliminary treatment. The DS‐SPCE sensor was found to be simple, efficient, fast, low cost, and greener than the other reported modified sensors, while providing better sensitivities to detect D/A and U/A simultaneously. Thus, the bare, unmodified DS‐SPCE can be a convenient sensing device for the routine analysis of D/A and U/A, without requiring any complex pretreatment and modification steps of the electrode.

Authors

Institutions

Publication Details

Journal
Electroanalysis
Published
2024-12-22
DOI
https://doi.org/10.1002/elan.202400291
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitive and Fast Simultaneous Voltammetric Determination of Dopamine and Uric Acid Using Simple Screen‐Printed Carbon Electrode Without Pretreatment and Modification

Mustafa Soylak, Abdul Niaz, Muhammad Balal Arain
1 citations
Electroanalysis
Electrochemical sensors and biosensors
0.21
article

Sensitive and Fast Simultaneous Voltammetric Determination of Dopamine and Uric Acid Using Simple Screen‐Printed Carbon Electrode Without Pretreatment and Modification

Mustafa Soylak, Abdul Niaz, Muhammad Balal Arain
article en
1 citations

Abstract

A simple, commercially available, unmodified screen‐printed carbon electrode (SPCE) was investigated for the simultaneous voltammetric determination of dopamine (D/A) and uric acid (U/A) in a medium of very low concentration of supporting electrolyte for the first time. The ordinary, simple SPCE from DropSens (DS‐SPCE) was found to be able to separate the overlapping peaks of D/A and U/A with a wide peak potential separation of 300 mV in a medium of very low concentration (0.001 M) of NaH 2 PO 4 as supporting electrolyte (buffer of low capacity) at pH 8.0. Medium of low concentration of electrolyte made it possible to expose the bare electrode surface for its high catalytic activity which resulted into a high peak current signals, particularly for D/A. The DS‐SPCE showed excellent electrocatalytic performance than the other SPCE. The effect of electrolyte concentration and pH on the electrocatalytic behavior of electrode were thoroughly discussed. The DS‐SPCE displayed a sensitive results in good linear ranges from 0.1–5 to 6–20 µM for D/A and 0.5–41.5 µM for U/A. The disposable electrode demonstrated better discrimination ability toward the detection of D/A and U/A over ascorbic acid and other potential interfering species. Moreover, the sensor presented sensitive and highly accurate results in human urine samples without preliminary treatment. The DS‐SPCE sensor was found to be simple, efficient, fast, low cost, and greener than the other reported modified sensors, while providing better sensitivities to detect D/A and U/A simultaneously. Thus, the bare, unmodified DS‐SPCE can be a convenient sensing device for the routine analysis of D/A and U/A, without requiring any complex pretreatment and modification steps of the electrode.

Electroanalysis
University of Karachi (PK), Turkish Academy of Sciences (TR), University of Science and Technology Bannu (PK), Erciyes University (TR)
Reduced inequalities, Peace, Justice and strong institutions
Openalex Percentile: Top 45%
Electrochemical sensors and biosensors
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.