DIAGNOSTIC ACCURACY OF THE ETDQ-7 IN ADULTS AT UNIVERSITY OF BENIN TEACHING HOSPITAL

Background: Diagnoses of Eustachian tube dysfunction in Benin City are typically made clinically or with tympanometry. The Eustachian Tube Dysfunction Questionnaire-7 (ETDQ-7) is a scoring system with potential as an alternative tool, particularly useful in resource-challenged settings. This novel tool may not have been previously investigated in this environment for its accuracy. Objective: The study aimed to compare the diagnostic accuracy of the Eustachian Tube Dysfunction Questionnaire-7 (ETDQ-7) to tympanometry (used as the reference standard) in identifying adult patients with Eustachian tube dysfunction at the ENT clinic of the University of Benin Teaching Hospital. Methodology: This was a hospital-based, prospective diagnostic accuracy study using a case-control design. A total of 150 study participants were recruited, including 75 case participants and 75 controls. The ETDQ-7 instrument was administered to all participants, followed by tympanometry for each. Data were analyzed using the IBM Statistical Package for the Social Sciences (IBM SPSS) version 26. Results: The diagnostic accuracy of the ETDQ-7 in the study group was found to be 68%, while in the control group, it was 85.4%. The Area Under the Curve (AUC) for the study group was approximately 0.75, and for the control group, it was approximately 0.80. Conclusion: The ETDQ-7 demonstrates moderate accuracy for the diagnosis of Eustachian tube dysfunction, making it a useful tool for adoption as a screening method. Its ease of administration, noninvasive nature, and reproducibility make it particularly advantageous in settings where resources are limited. However, due to its moderate specificity, it is best utilized as a preliminary screening tool rather than a definitive diagnostic method.

Authors

Publication Details

Journal
The American Journal of Interdisciplinary Innovations and Research
Published
2024-12-22
DOI
https://doi.org/10.37547/tajiir/volume06issue12-05
Primary Topic
Medical Coding and Health Information
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DIAGNOSTIC ACCURACY OF THE ETDQ-7 IN ADULTS AT UNIVERSITY OF BENIN TEACHING HOSPITAL

Odu Oji Kennedy, Uchefe Atuyota Okiemute, Okolugbo Emmanuel Nekwu, Okhaku Lami Amina
The American Journal of Interdisciplinary Innovations and Research
Medical Coding and Health Information
article

DIAGNOSTIC ACCURACY OF THE ETDQ-7 IN ADULTS AT UNIVERSITY OF BENIN TEACHING HOSPITAL

Odu Oji Kennedy, Uchefe Atuyota Okiemute, Okolugbo Emmanuel Nekwu, Okhaku Lami Amina
article en

Abstract

Background: Diagnoses of Eustachian tube dysfunction in Benin City are typically made clinically or with tympanometry. The Eustachian Tube Dysfunction Questionnaire-7 (ETDQ-7) is a scoring system with potential as an alternative tool, particularly useful in resource-challenged settings. This novel tool may not have been previously investigated in this environment for its accuracy. Objective: The study aimed to compare the diagnostic accuracy of the Eustachian Tube Dysfunction Questionnaire-7 (ETDQ-7) to tympanometry (used as the reference standard) in identifying adult patients with Eustachian tube dysfunction at the ENT clinic of the University of Benin Teaching Hospital. Methodology: This was a hospital-based, prospective diagnostic accuracy study using a case-control design. A total of 150 study participants were recruited, including 75 case participants and 75 controls. The ETDQ-7 instrument was administered to all participants, followed by tympanometry for each. Data were analyzed using the IBM Statistical Package for the Social Sciences (IBM SPSS) version 26. Results: The diagnostic accuracy of the ETDQ-7 in the study group was found to be 68%, while in the control group, it was 85.4%. The Area Under the Curve (AUC) for the study group was approximately 0.75, and for the control group, it was approximately 0.80. Conclusion: The ETDQ-7 demonstrates moderate accuracy for the diagnosis of Eustachian tube dysfunction, making it a useful tool for adoption as a screening method. Its ease of administration, noninvasive nature, and reproducibility make it particularly advantageous in settings where resources are limited. However, due to its moderate specificity, it is best utilized as a preliminary screening tool rather than a definitive diagnostic method.

The American Journal of Interdisciplinary Innovations and ResearchVol. 06(12)
Openalex Percentile: Top 67%
Medical Coding and Health Information
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.