Smart sensing of creatinine in urine samples: Leveraging Cu-nanowires/MoS2 quantum dots and machine learning

Serum creatinine (CRT) levels are key biomarkers for diagnosing, staging, and monitoring renal disease in clinical practice. In this work, copper nanowires (CuNW), and Molybdenum disulfide quantum dots (MSQD) modified glassy carbon electrode (GCE) were chosen to demonstrate the electrochemical detection of CRT in complex mixture and urine samples. The materials were characterized using various physical characterizations such as FESEM, XRD, UV, PL, and FT-Raman. The electrocatalytic activity of the sensor was investigated using cyclic voltammetry (CV), and differential pulse voltammetry (DPVs). Despite the elevated sensitivity and cost-effectiveness of electrochemical sensors, the performance of the sensors is constrained by the existence of interfering species that generate conflicting and overlapping electrochemical signatures. In order to address this issue, we implemented a machine learning (ML) approach to accurately quantify CRT levels in complex mixtures, as well as in urine samples. The ML algorithms employed are trained and tested on a large dataset, allowing them to effectively capture and analyze the variance in the electrochemical signatures, demonstrating the application of artificial intelligence. The proposed sensor exhibits linearity from 1.96 μM to 966.0 μM and shows the best performance in terms of limit-of-detection (LOD) of 2.3 μM in a complex mixture and 0.001 μM in real urine samples, with RMSE of 0.2 and 0.017 μM using artificial neural network and random forest ML models respectively. We anticipate that by further miniaturization of these sensors into point-of-care testing devices, renal diseases can be managed effectively. • A simple and cost-effective electrochemical sensor for the detection of creatinine. • The fabricated sensor detects creatinine in complex mixtures and urine samples. • Machine learning algorithms were applied for the validation of experimental data. • Challenges posed by interfering species that generate complex overlapping signals were addressed.

Authors

Institutions

Publication Details

Journal
Sensing and Bio-Sensing Research
Published
2024-12-22
DOI
https://doi.org/10.1016/j.sbsr.2024.100727
Citations
4
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smart sensing of creatinine in urine samples: Leveraging Cu-nanowires/MoS2 quantum dots and machine learning

Kiran Kumar Tadi, Chandranath Adak, Rajendra P. Shukla, Geethukrishnan et al.
4 citations
Sensing and Bio-Sensing Research
Electrochemical sensors and biosensors
0.83
article

Smart sensing of creatinine in urine samples: Leveraging Cu-nanowires/MoS2 quantum dots and machine learning

Kiran Kumar Tadi, Chandranath Adak, Rajendra P. Shukla, Geethukrishnan, Paresh Prakash Bagde, K.H. Sammishra
article en
4 citations

Abstract

Serum creatinine (CRT) levels are key biomarkers for diagnosing, staging, and monitoring renal disease in clinical practice. In this work, copper nanowires (CuNW), and Molybdenum disulfide quantum dots (MSQD) modified glassy carbon electrode (GCE) were chosen to demonstrate the electrochemical detection of CRT in complex mixture and urine samples. The materials were characterized using various physical characterizations such as FESEM, XRD, UV, PL, and FT-Raman. The electrocatalytic activity of the sensor was investigated using cyclic voltammetry (CV), and differential pulse voltammetry (DPVs). Despite the elevated sensitivity and cost-effectiveness of electrochemical sensors, the performance of the sensors is constrained by the existence of interfering species that generate conflicting and overlapping electrochemical signatures. In order to address this issue, we implemented a machine learning (ML) approach to accurately quantify CRT levels in complex mixtures, as well as in urine samples. The ML algorithms employed are trained and tested on a large dataset, allowing them to effectively capture and analyze the variance in the electrochemical signatures, demonstrating the application of artificial intelligence. The proposed sensor exhibits linearity from 1.96 μM to 966.0 μM and shows the best performance in terms of limit-of-detection (LOD) of 2.3 μM in a complex mixture and 0.001 μM in real urine samples, with RMSE of 0.2 and 0.017 μM using artificial neural network and random forest ML models respectively. We anticipate that by further miniaturization of these sensors into point-of-care testing devices, renal diseases can be managed effectively. • A simple and cost-effective electrochemical sensor for the detection of creatinine. • The fabricated sensor detects creatinine in complex mixtures and urine samples. • Machine learning algorithms were applied for the validation of experimental data. • Challenges posed by interfering species that generate complex overlapping signals were addressed.

Sensing and Bio-Sensing ResearchVol. 47
Indian Institute of Technology Patna (IN), North Carolina State University (US), Vels University (IN), Sacred Heart College (IN)
Openalex Percentile: Top 26%
Electrochemical sensors and biosensors
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.