Biological Dosimetry for Pu-239 Inhalation

“Dose–response“ and “radioactivity level in the body–response” relationships that were set earlier for three types of chromosomal aberrations (dicentrics, stable aberrations and total aberrations) enabled the development of the biodosimetry system. This system allows the estimation of individual doses and ²³⁹Pu activity body levels in Mayak PA workers due to acute or chronic inhalation of plutonium compounds that are characterised by low transportability. The relative error of individual radiation doses absorbed in the lungs estimated by the biodosimetry system (based on stable CA and total CA) varied between 5.4 and 83.6% (with an average of 39.8%). On the other hand, the relative error in the individual estimate of ²³⁹Pu activity in the body due to chronic exposure similarly varied within a relatively narrow range: from 6.2 to 51.6% (the average of 42.8%). The relative uncertainty of the dose estimate for acute plutonium exposure averaged around 35%.

Authors

Institutions

Publication Details

Journal
Радиационная биология Радиоэкология
Published
2024-12-22
DOI
https://doi.org/10.31857/s0869803124050066
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biological Dosimetry for Pu-239 Inhalation

Tamara V. Azizova, S. V. Osovets, O. A. Sinelschikova
Радиационная биология Радиоэкология
Radiation Dose and Imaging
article

Biological Dosimetry for Pu-239 Inhalation

Tamara V. Azizova, S. V. Osovets, O. A. Sinelschikova
article en

Abstract

“Dose–response“ and “radioactivity level in the body–response” relationships that were set earlier for three types of chromosomal aberrations (dicentrics, stable aberrations and total aberrations) enabled the development of the biodosimetry system. This system allows the estimation of individual doses and ²³⁹Pu activity body levels in Mayak PA workers due to acute or chronic inhalation of plutonium compounds that are characterised by low transportability. The relative error of individual radiation doses absorbed in the lungs estimated by the biodosimetry system (based on stable CA and total CA) varied between 5.4 and 83.6% (with an average of 39.8%). On the other hand, the relative error in the individual estimate of ²³⁹Pu activity in the body due to chronic exposure similarly varied within a relatively narrow range: from 6.2 to 51.6% (the average of 42.8%). The relative uncertainty of the dose estimate for acute plutonium exposure averaged around 35%.

Радиационная биология РадиоэкологияVol. 64(5)
Southern Urals Biophysics Institute, Federal Medical-Biological Agency (RU)
Clean water and sanitation
Openalex Percentile: Top 59%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.