Teaching learning based optimization algorithm for effective analysis of power quality using dynamic voltage restorer

In this study, the load voltage is dynamically restored utilising the dynamic voltage restorer (DVR) using the voltage injection approach. The injected voltage is generated using a voltage-source inverter (VSI), which is necessary to correct for the utility network's sag and swell characteristics voltage. The restoration process is dependent on the condition and quality of the utility system, i.e., it injects energy into the external system for the duration of voltage sag, and during voltage swell, energy is absorbed by the compensator from the external system, causing an rise in dc link voltage, which is connected across the VSI. In this study two different controllers are employed based on a learning based optimized algorithm. The simulation results are shown using two different controllers and the performance of the proposed controller is found to be a better one.

Authors

Institutions

Publication Details

Journal
International Journal of Informatics and Communication Technology (IJ-ICT)
Published
2024-12-22
DOI
https://doi.org/10.11591/ijict.v14i1.pp268-275
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Teaching learning based optimization algorithm for effective analysis of power quality using dynamic voltage restorer

Surender Reddy Salkuti, Soumya Ranjan Das
International Journal of Informatics and Communication Technology (IJ-ICT)
Power Quality and Harmonics
article

Teaching learning based optimization algorithm for effective analysis of power quality using dynamic voltage restorer

Surender Reddy Salkuti, Soumya Ranjan Das
article en

Abstract

In this study, the load voltage is dynamically restored utilising the dynamic voltage restorer (DVR) using the voltage injection approach. The injected voltage is generated using a voltage-source inverter (VSI), which is necessary to correct for the utility network's sag and swell characteristics voltage. The restoration process is dependent on the condition and quality of the utility system, i.e., it injects energy into the external system for the duration of voltage sag, and during voltage swell, energy is absorbed by the compensator from the external system, causing an rise in dc link voltage, which is connected across the VSI. In this study two different controllers are employed based on a learning based optimized algorithm. The simulation results are shown using two different controllers and the performance of the proposed controller is found to be a better one.

International Journal of Informatics and Communication Technology (IJ-ICT)Vol. 14(1)
Maharaja Engineering College (IN), Woosong University (KR)
Openalex Percentile: Top 78%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies