Development of a portable electrocoagulation unit for on-site treatment of washing machine wastewater

This study evaluated the effectiveness of the electrocoagulation method in treating wastewater from two laundries in the Huancavelica district of Peru, focusing on reducing chemical oxygen demand (COD) and monitoring temperature and pH levels. Over two weeks, treatments were conducted with varying current intensities (15 and 30 Amp/m²) and durations (15 and 40 minutes), mixing speed + time (20 and 40 rpm) alongside a control with 0 Amp/m² and 0 minutes. The initial untreated samples showed high COD levels, highlighting significant organic pollution. The results demonstrated substantial COD reductions across all treatments, with the most effective reduction observed at 15 Amp/m² for 15 minutes, achieving COD levels of 366.50 mg/L in Laundry 1 and 348.50 mg/L in Laundry 2. This significant decrease complies with Supreme Decree No. 010-2019-VIVIENDA, which mandates COD levels below 1000 mg/L for non-domestic wastewater discharges. Temperature and pH variations were also analyzed, revealing that the electrocoagulation process increased the temperature moderately, with averages ranging from 15.15°C to 36.80°C in Laundry 1 and 15.65°C to 34.80°C in Laundry 2. The pH levels remained slightly alkaline, ranging from 8.47 to 10.55 in Laundry 1 and 9.47 to 10.62 in Laundry 2, indicating that the process maintains acceptable alkalinity. In conclusion, the electrocoagulation method effectively reduces COD, maintains moderate temperature increases, and slightly alters pH levels, making it a viable option for treating industrial wastewater. These findings support the potential for electrocoagulation to enhance wastewater management practices, promoting environmental sustainability and regulatory compliance.

Authors

Institutions

Publication Details

Journal
Journal of Experimental Biology and Agricultural Sciences
Published
2024-11-29
DOI
https://doi.org/10.18006/2024.12(5).676.685
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a portable electrocoagulation unit for on-site treatment of washing machine wastewater

Russbelt Yaulilahua-Huacho, José Carlos Ayuque-Rojas, Carlos Dueñas-Jurado, Víctor Guillermo Sánchez Araujo et al.
Journal of Experimental Biology and Agricultural Sciences
Advanced oxidation water treatment
article

Development of a portable electrocoagulation unit for on-site treatment of washing machine wastewater

Russbelt Yaulilahua-Huacho, José Carlos Ayuque-Rojas, Carlos Dueñas-Jurado, Víctor Guillermo Sánchez Araujo, Jorge Luis Huere-Peña, Mabel Escobar-Soldevilla, Pedro Antonio Palomino Pastrana, Herbert Rodas-Ccopa, Edwin Javier Ccente-Chancha, Russell Mejia-Cayllahua, Brian Elgin Garcia-Riveros
article en

Abstract

This study evaluated the effectiveness of the electrocoagulation method in treating wastewater from two laundries in the Huancavelica district of Peru, focusing on reducing chemical oxygen demand (COD) and monitoring temperature and pH levels. Over two weeks, treatments were conducted with varying current intensities (15 and 30 Amp/m²) and durations (15 and 40 minutes), mixing speed + time (20 and 40 rpm) alongside a control with 0 Amp/m² and 0 minutes. The initial untreated samples showed high COD levels, highlighting significant organic pollution. The results demonstrated substantial COD reductions across all treatments, with the most effective reduction observed at 15 Amp/m² for 15 minutes, achieving COD levels of 366.50 mg/L in Laundry 1 and 348.50 mg/L in Laundry 2. This significant decrease complies with Supreme Decree No. 010-2019-VIVIENDA, which mandates COD levels below 1000 mg/L for non-domestic wastewater discharges. Temperature and pH variations were also analyzed, revealing that the electrocoagulation process increased the temperature moderately, with averages ranging from 15.15°C to 36.80°C in Laundry 1 and 15.65°C to 34.80°C in Laundry 2. The pH levels remained slightly alkaline, ranging from 8.47 to 10.55 in Laundry 1 and 9.47 to 10.62 in Laundry 2, indicating that the process maintains acceptable alkalinity. In conclusion, the electrocoagulation method effectively reduces COD, maintains moderate temperature increases, and slightly alters pH levels, making it a viable option for treating industrial wastewater. These findings support the potential for electrocoagulation to enhance wastewater management practices, promoting environmental sustainability and regulatory compliance.

Journal of Experimental Biology and Agricultural SciencesVol. 12(5)
Universidad Nacional José María Arguedas (PE), Universidad Nacional de Huancavelica (PE)
Openalex Percentile: Top 77%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.