Digitalization of a calibration laboratory: Batch calibration

The Metrology and Calibration Centre (CMC) at the National Institute of Aerospace Technology (INTA) has introduced an innovative tool designed to enhance the efficiency and effectiveness of calibration processes within its facilities. This cutting-edge software enables technicians to conduct multiple calibrations simultaneously, provided the requisite experimental setup is in place. Developed with a focus on streamlining the entire calibration workflow, from data acquisition to certificate issuance, the software ensures compliance with the ISO/IEC 17025 standard. Through rigorous testing, the CMC verified the software's performance using devices employed for monitoring ambient conditions (temperature and humidity) across various INTA test laboratories. Notably, these devices underwent batch calibration in groups of six, resulting in a sixfold reduction in experimentation time. Although the associated paperwork was reduced, the necessity to maintain traceability and issue individual calibration certificates for each device offsets the time savings.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2024-12-22
DOI
https://doi.org/10.1016/j.measen.2024.101498
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digitalization of a calibration laboratory: Batch calibration

Fernando J. Pérez-Sanz, R. Sanz, José Gallegos, Robert Benyon Puig et al.
Measurement Sensors
Sensor Technology and Measurement Systems
article

Digitalization of a calibration laboratory: Batch calibration

Fernando J. Pérez-Sanz, R. Sanz, José Gallegos, Robert Benyon Puig, I. Mohino Herranz, T. Vicente Mussons
article en

Abstract

The Metrology and Calibration Centre (CMC) at the National Institute of Aerospace Technology (INTA) has introduced an innovative tool designed to enhance the efficiency and effectiveness of calibration processes within its facilities. This cutting-edge software enables technicians to conduct multiple calibrations simultaneously, provided the requisite experimental setup is in place. Developed with a focus on streamlining the entire calibration workflow, from data acquisition to certificate issuance, the software ensures compliance with the ISO/IEC 17025 standard. Through rigorous testing, the CMC verified the software's performance using devices employed for monitoring ambient conditions (temperature and humidity) across various INTA test laboratories. Notably, these devices underwent batch calibration in groups of six, resulting in a sixfold reduction in experimentation time. Although the associated paperwork was reduced, the necessity to maintain traceability and issue individual calibration certificates for each device offsets the time savings.

Measurement SensorsVol. 38
Instituto Nacional de Técnica Aeroespacial (ES)
Openalex Percentile: Top 73%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.