Comparative Evaluation of Fracture Resistance, Deformation and Patency Efficiency of Reciprocating and Rotary Glide Path Files: An In vitro Study

Aims: To evaluate the performance of reciprocating and rotary Glide Path files in human permanent mandibular molars, focusing on instrument fracture, deformation, and patency rates. Study Design: The study was a comparative analysis conducted to evaluate the incidence of instrument failure and the success rates in reaching working length using different file systems. Place and Duration of Study: The study was conducted on human permanent mandibular molars at the University of Fortaleza, from January 2024 to June 2024. Methodology: A total of 150 human permanent mandibular molars were selected and randomly assigned into three groups (n=50). The groups were treated with R-Pilot®, Wave One Gold Glider®, and ProDesign Logic® 15.03 files. Instrument fracture and deformation rates were recorded, and the percentage of Glide Path instruments that reached the working length was noted. Data were managed and analyzed using Excel and statistical analyses were performed using Stata 10 software. Results: The Wave One Gold Glider® group exhibited the highest incidence of fractures and deformations, with only 4 intact files at the conclusion of the study, showing statistically worse results compared to the other file systems. No significant differences were found between the R-Pilot® and ProDesign Logic® groups. The mesiobuccal root canals had the highest failure rate in achieving foraminal patency, with 24 canals not reaching patency. Conversely, the mesiolingual root canals were the most successful, achieving initial exploration in 102 canals. Conclusion: The reciprocating system Wave One Gold Glider® did not show superiority over the rotary system Pro Design Logic® under the conditions tested. The findings also highlight the high patency rates achieved by Glide Path files and the differences in performance between the various systems tested. The Glide Path files demonstrated high patency rates, ranging from 81% to 88%.

Authors

Institutions

Publication Details

Journal
Journal of Advances in Medicine and Medical Research
Published
2024-12-21
DOI
https://doi.org/10.9734/jammr/2024/v36i125680
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Evaluation of Fracture Resistance, Deformation and Patency Efficiency of Reciprocating and Rotary Glide Path Files: An In vitro Study

Luiz Carlos Trévia Morais Correia Viana, Fábio de Almeida Gomes, José Evando da Silva-Filho, Luiz Carlos Costa Madeira Alves et al.
Journal of Advances in Medicine and Medical Research
Orthopaedic implants and arthroplasty
article

Comparative Evaluation of Fracture Resistance, Deformation and Patency Efficiency of Reciprocating and Rotary Glide Path Files: An In vitro Study

Luiz Carlos Trévia Morais Correia Viana, Fábio de Almeida Gomes, José Evando da Silva-Filho, Luiz Carlos Costa Madeira Alves, Eduardo Diogo Gurgel Filho, Gabriela Mendes Amador, Júlia Magalhães-Saldanha
article en

Abstract

Aims: To evaluate the performance of reciprocating and rotary Glide Path files in human permanent mandibular molars, focusing on instrument fracture, deformation, and patency rates. Study Design: The study was a comparative analysis conducted to evaluate the incidence of instrument failure and the success rates in reaching working length using different file systems. Place and Duration of Study: The study was conducted on human permanent mandibular molars at the University of Fortaleza, from January 2024 to June 2024. Methodology: A total of 150 human permanent mandibular molars were selected and randomly assigned into three groups (n=50). The groups were treated with R-Pilot®, Wave One Gold Glider®, and ProDesign Logic® 15.03 files. Instrument fracture and deformation rates were recorded, and the percentage of Glide Path instruments that reached the working length was noted. Data were managed and analyzed using Excel and statistical analyses were performed using Stata 10 software. Results: The Wave One Gold Glider® group exhibited the highest incidence of fractures and deformations, with only 4 intact files at the conclusion of the study, showing statistically worse results compared to the other file systems. No significant differences were found between the R-Pilot® and ProDesign Logic® groups. The mesiobuccal root canals had the highest failure rate in achieving foraminal patency, with 24 canals not reaching patency. Conversely, the mesiolingual root canals were the most successful, achieving initial exploration in 102 canals. Conclusion: The reciprocating system Wave One Gold Glider® did not show superiority over the rotary system Pro Design Logic® under the conditions tested. The findings also highlight the high patency rates achieved by Glide Path files and the differences in performance between the various systems tested. The Glide Path files demonstrated high patency rates, ranging from 81% to 88%.

Journal of Advances in Medicine and Medical ResearchVol. 36(12)
Universidade de Fortaleza (BR), Hospital de Messejana (BR), Fundação Edson Queiroz (BR)
Openalex Percentile: Top 56%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.