The Heisenberg-RIXS instrument at the European XFEL

Resonant inelastic X-ray scattering (RIXS) is an ideal X-ray spectroscopy method to push the combination of energy and time resolutions to the Fourier transform ultimate limit, because it is unaffected by the core-hole lifetime energy broadening. Also, in pump-probe experiments the interaction time is made very short by the same core-hole lifetime. RIXS is very photon hungry so it takes great advantage from high-repetition-rate pulsed X-ray sources like the European XFEL. The Heisenberg RIXS instrument is designed for RIXS experiments in the soft X-ray range with energy resolution approaching the Fourier and the Heisenberg limits. It is based on a spherical grating with variable line spacing and a position-sensitive 2D detector. Initially, two gratings were installed to adequately cover the whole photon energy range. With optimized spot size on the sample and small pixel detector the energy resolution can be better than 40 meV (90 meV) at any photon energy below 1000 eV with the high-resolution (high-transmission) grating. At the SCS instrument of the European XFEL the spectrometer can be easily positioned thanks to air pads on a high-quality floor, allowing the scattering angle to be continuously adjusted over the 65-145° range. It can be coupled to two different sample interaction chambers, one for liquid jets and one for solids, each state-of-the-art equipped and compatible for optical laser pumping in collinear geometry. The measured performances, in terms of energy resolution and count rate on the detector, closely match design expectations. The Heisenberg RIXS instrument has been open to public users since the summer of 2022.

Authors

Institutions

Publication Details

Journal
Journal of Synchrotron Radiation
Published
2024-12-20
DOI
https://doi.org/10.1107/s1600577524010890
Citations
7
Primary Topic
X-ray Spectroscopy and Fluorescence Analysis
Type
article
Field-Weighted Citation Impact
4.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Heisenberg-RIXS instrument at the European XFEL

Simone Techert, Alexander Föhlisch, Piter S. Miedema, Robert Carley et al.
7 citations
Journal of Synchrotron Radiation
X-ray Spectroscopy and Fluorescence Analysis
4.25
article

The Heisenberg-RIXS instrument at the European XFEL

Simone Techert, Alexander Föhlisch, Piter S. Miedema, Robert Carley, Luigi Adriano, David Hickin, Annette Pietzsch, Jan Torben Delitz, Christian Sohrt, Tim Laarmann, Vinícius Vaz da Cruz, Y. Y. Peng, Zhong Yin, Stefan Neppl, Sergii Parchenko, Christian Weniger, Nahid Ghodrati, Patrick Geßler, T. Gießel, Benjamin E. Van Kuiken, G. Ghiringhelli, Carsten Broers, Jana Buchheim, Andreas Scherz, Grzegorz Gwalt, Torben Reuss, Justine Schlappa, Laurent Mercadier, Martin Teichmann, Sebastian Eckert, M. Izquierdo, B. Langer, Frank Siewert, Giuseppe Mercurio, С. Л. Молодцов, Simo Huotari, Christian Schroeter, B. Baranasic, Marijan Stupar, Leonardo Martinelli, Le Phuong Hoang, Andréy Sokolov, F. Senf, Sreeju Sreekantan Nair Lalithambika, Giacomo Merzoni, Robby Buechner, Chunyu Liu, Natalia Gerasimova
article en
7 citations

Abstract

Resonant inelastic X-ray scattering (RIXS) is an ideal X-ray spectroscopy method to push the combination of energy and time resolutions to the Fourier transform ultimate limit, because it is unaffected by the core-hole lifetime energy broadening. Also, in pump-probe experiments the interaction time is made very short by the same core-hole lifetime. RIXS is very photon hungry so it takes great advantage from high-repetition-rate pulsed X-ray sources like the European XFEL. The Heisenberg RIXS instrument is designed for RIXS experiments in the soft X-ray range with energy resolution approaching the Fourier and the Heisenberg limits. It is based on a spherical grating with variable line spacing and a position-sensitive 2D detector. Initially, two gratings were installed to adequately cover the whole photon energy range. With optimized spot size on the sample and small pixel detector the energy resolution can be better than 40 meV (90 meV) at any photon energy below 1000 eV with the high-resolution (high-transmission) grating. At the SCS instrument of the European XFEL the spectrometer can be easily positioned thanks to air pads on a high-quality floor, allowing the scattering angle to be continuously adjusted over the 65-145° range. It can be coupled to two different sample interaction chambers, one for liquid jets and one for solids, each state-of-the-art equipped and compatible for optical laser pumping in collinear geometry. The measured performances, in terms of energy resolution and count rate on the detector, closely match design expectations. The Heisenberg RIXS instrument has been open to public users since the summer of 2022.

Journal of Synchrotron RadiationVol. 32(1)
University of Helsinki (FI), University of Potsdam (DE), Helmholtz-Zentrum Berlin für Materialien und Energie (DE), Deutsches Elektronen-Synchrotron DESY (DE), Cameco (Germany) (DE), European X-Ray Free-Electron Laser (DE), Politecnico di Milano (IT)
Deutsche Forschungsgemeinschaft, H2020 European Research Council
Affordable and clean energy
Openalex Percentile: Top 5%
X-ray Spectroscopy and Fluorescence Analysis
4.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.