Seismic performance of reinforcement-lapped square CFST column base

• A novel column base with lapped reinforcements was proposed for square CFST column. • A cyclic loading test was conducted on the column base specimens to investigate key parameters of reinforcement ratio, lap length of lapped reinforcements, and configuration of PBL. • A finite element (FE) model for the column base was developed and parametric study was performed. • A calculation method for determining the combined compression-bending capacity along with reasonable constructional measures was proposed. This study proposes a square concrete-filled steel tubular (CFST) column base with lapped longitudinal reinforcements, and focuses on the investigation of its seismic performance experimentally and analytically. A quasi-static test on five reinforcement-lapped square CFST column bases is first conducted to evaluate the seismic performance, considering the key parameters of reinforcement ratio, lap length of lapped reinforcements, and configuration of the perfobond rib (PBL). The test results of failure modes, bearing capacity, ductility, energy dissipation capacity, and stress distribution, indicating that the proposed column base exhibits good seismic performance. The bearing capacity, ductility, and energy dissipation capacity are comparable to traditional embedded CFST column bases. To further investigate the force transfer path and stress distribution characteristics of the column bases, the software ABAQUS is used to establish a finite element model . Additionally, a calculation method for determining the combined compression-bending capacity is proposed. Validated against the experimental results, the proposed calculation method accurately predicts the bearing capacity of reinforcement-lapped square CFST column bases, making it suitable for practical applications.

Authors

Institutions

Publication Details

Journal
Thin-Walled Structures
Published
2024-12-20
DOI
https://doi.org/10.1016/j.tws.2024.112867
Citations
2
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic performance of reinforcement-lapped square CFST column base

Shiyong Jiang, Yingying Yu, Yuanlong Yang, Yohchia Frank Chen et al.
2 citations
Thin-Walled Structures
Structural Load-Bearing Analysis
0.52
article

Seismic performance of reinforcement-lapped square CFST column base

Shiyong Jiang, Yingying Yu, Yuanlong Yang, Yohchia Frank Chen, Guojun Wang, Lanhui Guo
article en
2 citations

Abstract

• A novel column base with lapped reinforcements was proposed for square CFST column. • A cyclic loading test was conducted on the column base specimens to investigate key parameters of reinforcement ratio, lap length of lapped reinforcements, and configuration of PBL. • A finite element (FE) model for the column base was developed and parametric study was performed. • A calculation method for determining the combined compression-bending capacity along with reasonable constructional measures was proposed. This study proposes a square concrete-filled steel tubular (CFST) column base with lapped longitudinal reinforcements, and focuses on the investigation of its seismic performance experimentally and analytically. A quasi-static test on five reinforcement-lapped square CFST column bases is first conducted to evaluate the seismic performance, considering the key parameters of reinforcement ratio, lap length of lapped reinforcements, and configuration of the perfobond rib (PBL). The test results of failure modes, bearing capacity, ductility, energy dissipation capacity, and stress distribution, indicating that the proposed column base exhibits good seismic performance. The bearing capacity, ductility, and energy dissipation capacity are comparable to traditional embedded CFST column bases. To further investigate the force transfer path and stress distribution characteristics of the column bases, the software ABAQUS is used to establish a finite element model . Additionally, a calculation method for determining the combined compression-bending capacity is proposed. Validated against the experimental results, the proposed calculation method accurately predicts the bearing capacity of reinforcement-lapped square CFST column bases, making it suitable for practical applications.

Thin-Walled StructuresVol. 209
Pennsylvania State University (US), Chongqing University (CN), Xinjiang Agricultural University (CN), China Coal Technology and Engineering Group Corp (China) (CN), Heilongjiang Institute of Technology (CN), Chongqing Jiaotong University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Climate action
Openalex Percentile: Top 34%
Structural Load-Bearing Analysis
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.