Yin-Yang Staining Technique to Create a Nonstained Internal Limiting Membrane Flap to Cover Large Idiopathic Macular Holes

<b>Purpose:</b> To describe a modified technique for negative and positive (Yin-Yang) staining of the internal limiting membrane (ILM) to create a nonstained ILM flap that covers large idiopathic macular holes (MHs). <b>Methods:</b> Consecutive patients with large idiopathic MHs (>400 μm) were prospectively included in the study. After the central vitreous was removed, a droplet of triamcinolone acetonide was injected, covering the MH and surrounding area. Subsequently, indocyanine green (ICG) was injected to stain the outer area of the ILM, followed by creation of a flap from the temporal stained area. Finally, the nonstained ILM flap was inverted to cover the MH. The main outcomes included the best-corrected visual acuity (BCVA), macular contour, and integrity of the outer retina. <b>Results:</b> This study comprised 31 patients (31 eyes). Of the eyes, 28 (90.3%) achieved primary MH closure. The mean minimum linear diameter and base diameter of the MH were 593 ± 119 μm and 1082 ± 242 μm, respectively. At the 6-month follow-up, 12 eyes (38.7%) and 9 eyes (29.0%) had regained a U-shaped or V-shaped macular contour, respectively. In addition, the mean logMAR BCVA improved from 1.06 ± 0.30 preoperatively to 0.56 ± 0.31 (<i>P</i> < .001). Twenty-one eyes (67.7%) and 16 eyes (51.6%) had regained integrity of the external limiting membrane and ellipsoid zone, respectively, at the 6-month follow-up. <b>Conclusions:</b> The modified ILM staining technique using triamcinolone acetonide and ICG sequentially is a safe and effective method of creating a nonstained ILM flap that covers large MHs and prevents the foveal area from coming into direct contact with ICG.

Authors

Institutions

Publication Details

Journal
Journal of VitreoRetinal Diseases
Published
2024-12-21
DOI
https://doi.org/10.1177/24741264241308486
Citations
1
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Yin-Yang Staining Technique to Create a Nonstained Internal Limiting Membrane Flap to Cover Large Idiopathic Macular Holes

Shuwen Xing, Bangjun Chen, Zhaotian Zhang, Yao Ni
1 citations
Journal of VitreoRetinal Diseases
Retinal and Macular Surgery
0.40
article

Yin-Yang Staining Technique to Create a Nonstained Internal Limiting Membrane Flap to Cover Large Idiopathic Macular Holes

Shuwen Xing, Bangjun Chen, Zhaotian Zhang, Yao Ni
article en
1 citations

Abstract

<b>Purpose:</b> To describe a modified technique for negative and positive (Yin-Yang) staining of the internal limiting membrane (ILM) to create a nonstained ILM flap that covers large idiopathic macular holes (MHs). <b>Methods:</b> Consecutive patients with large idiopathic MHs (>400 μm) were prospectively included in the study. After the central vitreous was removed, a droplet of triamcinolone acetonide was injected, covering the MH and surrounding area. Subsequently, indocyanine green (ICG) was injected to stain the outer area of the ILM, followed by creation of a flap from the temporal stained area. Finally, the nonstained ILM flap was inverted to cover the MH. The main outcomes included the best-corrected visual acuity (BCVA), macular contour, and integrity of the outer retina. <b>Results:</b> This study comprised 31 patients (31 eyes). Of the eyes, 28 (90.3%) achieved primary MH closure. The mean minimum linear diameter and base diameter of the MH were 593 ± 119 μm and 1082 ± 242 μm, respectively. At the 6-month follow-up, 12 eyes (38.7%) and 9 eyes (29.0%) had regained a U-shaped or V-shaped macular contour, respectively. In addition, the mean logMAR BCVA improved from 1.06 ± 0.30 preoperatively to 0.56 ± 0.31 (<i>P</i> < .001). Twenty-one eyes (67.7%) and 16 eyes (51.6%) had regained integrity of the external limiting membrane and ellipsoid zone, respectively, at the 6-month follow-up. <b>Conclusions:</b> The modified ILM staining technique using triamcinolone acetonide and ICG sequentially is a safe and effective method of creating a nonstained ILM flap that covers large MHs and prevents the foveal area from coming into direct contact with ICG.

Journal of VitreoRetinal DiseasesVol. 9(3)
Sun Yat-sen University (CN)
Openalex Percentile: Top 31%
Retinal and Macular Surgery
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Yin-Yang Staining Technique to Create a Nonstained Internal Limiting Membrane Flap to Cover Large Idiopathic Macular Holes — Shuwen Xing, Bangjun Chen, et al. · Journal of VitreoRetinal Diseases (2024) | TGRS Research Map | TGRS