Harnessing Two Measurement Techniques to Assess the Internal Structure of SFRC

The article describes the examination of the internal structure of concrete reinforced with steel fibers using two non-destructive measurement techniques: a method using ultrasonic waves and a method using electromagnetic induction. The ultrasonic method allowed for the determination of material defects resulting from the non-uniform distribution of fibers in the space of the tested sample bodies. The method using electromagnetic induction allowed for the identification of fiber content. Research has shown that fiber concrete, characterized by a relatively high content of steel fibers (above 1.5 % by volume), is susceptible to the formation of material discontinuities in its internal structure. This phenomenon occurs to a very small extent in concrete with steel fiber content below 1.5 %.

Authors

Publication Details

Journal
Pomiary Automatyka Robotyka
Published
2024-12-11
DOI
https://doi.org/10.14313/par_254/111
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harnessing Two Measurement Techniques to Assess the Internal Structure of SFRC

Machi Zawidzki, Jacek Katzer, Janusz Kobaka
Pomiary Automatyka Robotyka
Non-Destructive Testing Techniques
article

Harnessing Two Measurement Techniques to Assess the Internal Structure of SFRC

Machi Zawidzki, Jacek Katzer, Janusz Kobaka
article en

Abstract

The article describes the examination of the internal structure of concrete reinforced with steel fibers using two non-destructive measurement techniques: a method using ultrasonic waves and a method using electromagnetic induction. The ultrasonic method allowed for the determination of material defects resulting from the non-uniform distribution of fibers in the space of the tested sample bodies. The method using electromagnetic induction allowed for the identification of fiber content. Research has shown that fiber concrete, characterized by a relatively high content of steel fibers (above 1.5 % by volume), is susceptible to the formation of material discontinuities in its internal structure. This phenomenon occurs to a very small extent in concrete with steel fiber content below 1.5 %.

Pomiary Automatyka RobotykaVol. 28(4)
Sustainable cities and communities
Openalex Percentile: Top 76%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.