Shear capacity of single- and double-layered gypsum board to steel stud screw connections in non-structural partitions

Gypsum steel-stud partition walls are composed of light-gauge, cold-formed steel studs and gypsum boards attached with self-drilling screws. These non-structural elements are commonly used in volumetric modular building structures serving as partitions or exterior walls. Volumetric modular building structures are prefabricated, prefinished constructions where three-dimensional units, known as modules, are built in a factory and then transported to the construction site where they are placed and interconnected. The volumetric modules experience different loading scenarios during handling and transportation. While the modules may be designed to resist transportation and handling loads structurally, damage to nonstructural elements, such as gypsum board to stud connections, can still occur even under lower amplitude excitations. These non-structural damages, if not avoided, will require additional on-site repairs, leading to an increase in the overall costs of modular projects. This study investigates the shear capacity and damage mechanisms of gypsum board to steel stud screw connections. A series of experimental tests are performed to determine the capacity of these connections varying with the number of gypsum board layers (one- or two-layer), fastener edge distance and direction of loading (parallel or perpendicular to the edge). Finally, an analytical formulation was proposed to estimate the shear capacity of these connections. Results indicate that the distance of fasteners to the gypsum board edges dramatically affects the behavior of these connections. The connection capacity at the damage state and the failure modes can fairly be predicted through the proposed analytical approach, showing a reasonable match with experimental results. • Shear capacity of the single- and double-layered GSCs is investigated. • Loading direction effect, parallel and perpendicular to gypsum edge, on GSC capacity. • Minimum edge distances are proposed for GSCs under different loading directions. • Analytical formulations are proposed for predicting the shear capacity of GSCs.

Authors

Institutions

Publication Details

Journal
Thin-Walled Structures
Published
2024-12-21
DOI
https://doi.org/10.1016/j.tws.2024.112844
Citations
4
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shear capacity of single- and double-layered gypsum board to steel stud screw connections in non-structural partitions

Charles‐Philippe Lamarche, Ehsan Bazarchi, Saeed Mohebbi
4 citations
Thin-Walled Structures
Structural Load-Bearing Analysis
1.04
article

Shear capacity of single- and double-layered gypsum board to steel stud screw connections in non-structural partitions

Charles‐Philippe Lamarche, Ehsan Bazarchi, Saeed Mohebbi
article en
4 citations

Abstract

Gypsum steel-stud partition walls are composed of light-gauge, cold-formed steel studs and gypsum boards attached with self-drilling screws. These non-structural elements are commonly used in volumetric modular building structures serving as partitions or exterior walls. Volumetric modular building structures are prefabricated, prefinished constructions where three-dimensional units, known as modules, are built in a factory and then transported to the construction site where they are placed and interconnected. The volumetric modules experience different loading scenarios during handling and transportation. While the modules may be designed to resist transportation and handling loads structurally, damage to nonstructural elements, such as gypsum board to stud connections, can still occur even under lower amplitude excitations. These non-structural damages, if not avoided, will require additional on-site repairs, leading to an increase in the overall costs of modular projects. This study investigates the shear capacity and damage mechanisms of gypsum board to steel stud screw connections. A series of experimental tests are performed to determine the capacity of these connections varying with the number of gypsum board layers (one- or two-layer), fastener edge distance and direction of loading (parallel or perpendicular to the edge). Finally, an analytical formulation was proposed to estimate the shear capacity of these connections. Results indicate that the distance of fasteners to the gypsum board edges dramatically affects the behavior of these connections. The connection capacity at the damage state and the failure modes can fairly be predicted through the proposed analytical approach, showing a reasonable match with experimental results. • Shear capacity of the single- and double-layered GSCs is investigated. • Loading direction effect, parallel and perpendicular to gypsum edge, on GSC capacity. • Minimum edge distances are proposed for GSCs under different loading directions. • Analytical formulations are proposed for predicting the shear capacity of GSCs.

Thin-Walled StructuresVol. 208
Université de Sherbrooke (CA)
Openalex Percentile: Top 24%
Structural Load-Bearing Analysis
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.