Flow drilling and flow tapping as a mean to improve the fatigue life of specimens representing plate-type orthopedic implants

• Flow processing induce ultrafine grain structure and work hardening. • Crest folds are created by flow tapping. • The fatigue life of flow formed holes is shorter than its conventional counterpart. • Folds are preferential fatigue crack initiation sites. • Flow forming increase the amount of sigma phase and delta ferrite. This study investigates the impact of flow drilling and flow tapping on the microstructure, microhardness, and fatigue life of 316L stainless steel specimens, which are designed to simulate plate-type orthopedic implants. In this novel approach, threaded holes are created by combining both cutting and deformation techniques. Three methods are examined: cut drilling with cut tapping, flow drilling with cut tapping, and cut drilling with flow tapping. The resulting specimens are analyzed through microscopic observations, microhardness testing, and four-point bending fatigue tests, conducted in accordance with ASTM standards. The S-N curves and fractographic analyses reveal that cutting methods generally offer superior fatigue performance. At the lowest stress level, the average fatigue life of the flow tapped specimens is 4.10 5 cycles, whereas specimens with holes formed with cutting method exhibit an average fatigue life of 1.5x10 6 . Specifically, cut threads are free of discontinuities, whereas flow threads systematically had crest folds. These folds are sites for crack initiation that contributes to the reduction of fatigue lives. Furthermore, the presence of the sigma phase, related to flow drilling and flow tapping, contribute to material embrittlement, which adversely affects fatigue life. Although deformation methods did not yield encouraging results for the 316L specimens, the characteristics they impart, such as the formation of ultrafine grains, may prove beneficial for other materials and applications. This study is the first to evaluate the fatigue life of threaded holes produced through a combination of cutting and deforming manufacturing methods.

Authors

Institutions

Publication Details

Journal
Engineering Failure Analysis
Published
2024-12-21
DOI
https://doi.org/10.1016/j.engfailanal.2024.109212
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flow drilling and flow tapping as a mean to improve the fatigue life of specimens representing plate-type orthopedic implants

Yann Macé, Myriam Brochu, Mohamed Akram Mechter, Léa Romain et al.
Engineering Failure Analysis
Orthopaedic implants and arthroplasty
article

Flow drilling and flow tapping as a mean to improve the fatigue life of specimens representing plate-type orthopedic implants

Yann Macé, Myriam Brochu, Mohamed Akram Mechter, Léa Romain, Benjamin Hervé
article en

Abstract

• Flow processing induce ultrafine grain structure and work hardening. • Crest folds are created by flow tapping. • The fatigue life of flow formed holes is shorter than its conventional counterpart. • Folds are preferential fatigue crack initiation sites. • Flow forming increase the amount of sigma phase and delta ferrite. This study investigates the impact of flow drilling and flow tapping on the microstructure, microhardness, and fatigue life of 316L stainless steel specimens, which are designed to simulate plate-type orthopedic implants. In this novel approach, threaded holes are created by combining both cutting and deformation techniques. Three methods are examined: cut drilling with cut tapping, flow drilling with cut tapping, and cut drilling with flow tapping. The resulting specimens are analyzed through microscopic observations, microhardness testing, and four-point bending fatigue tests, conducted in accordance with ASTM standards. The S-N curves and fractographic analyses reveal that cutting methods generally offer superior fatigue performance. At the lowest stress level, the average fatigue life of the flow tapped specimens is 4.10 5 cycles, whereas specimens with holes formed with cutting method exhibit an average fatigue life of 1.5x10 6 . Specifically, cut threads are free of discontinuities, whereas flow threads systematically had crest folds. These folds are sites for crack initiation that contributes to the reduction of fatigue lives. Furthermore, the presence of the sigma phase, related to flow drilling and flow tapping, contribute to material embrittlement, which adversely affects fatigue life. Although deformation methods did not yield encouraging results for the 316L specimens, the characteristics they impart, such as the formation of ultrafine grains, may prove beneficial for other materials and applications. This study is the first to evaluate the fatigue life of threaded holes produced through a combination of cutting and deforming manufacturing methods.

Engineering Failure AnalysisVol. 169
École nationale supérieure de techniques avancées Bretagne (FR), Polytech Lille (FR)
Canada Research Chairs
Openalex Percentile: Top 56%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.