Studies on Square Wave and Cyclic Voltammetric Behavior of 1,2- and 1,4-Dihydroxybenzenes and Their Derivatives in Acetic Acid, Ethyl Acetate and Mixtures of the Two

An electrochemical investigation of 1,2- and 1,4-dihydroxybenzenes was carried out with platinum macro- and microelectrodes using square wave and cyclic voltammetry techniques. Furthermore, the effect of the two solvents-acetic acid and ethyl acetate-was compared. When using square wave voltammetry, signals only appeared at lower frequencies and only when the supporting electrolyte was in excess, as expected due to the relatively low permittivity of the used solvents. The behavior of hydroquinone and catechol did not differ significantly from that of their derivatives (dihydroxybenzaldehydes, dihydroxybenzoic acids and 2',5'-dihydroxyacetophenone). When the cyclic voltammetric experiments using a microelectrode were extended to higher anodic potentials, electrode fouling was very significant in ethyl acetate after the potential region where steady-state oxidation to the corresponding quinone occurs. The substituent effect was not significant here either, which was proven by using different functional groups in different positions. In contrast, the position had a dramatic influence on the susceptibility to electropolymerization, as 1,2-dihydroxybenzenes-independent of the nature of the substituent on the benzene ring-deactivated the electrode, while 1,4-dihydroxybenzenes did not, possibly due to the different solubilities of the polymers formed from the primary oxidation product (quinones). A user-friendly analytical procedure is also proposed that uses an electropolymerization reaction and does not require frequent cleaning of the electrode via polishing, which is required usually especially with a microelectrode.

Authors

Institutions

Publication Details

Journal
Methods and Protocols
Published
2024-12-20
DOI
https://doi.org/10.3390/mps7060102
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Studies on Square Wave and Cyclic Voltammetric Behavior of 1,2- and 1,4-Dihydroxybenzenes and Their Derivatives in Acetic Acid, Ethyl Acetate and Mixtures of the Two

László Kiss
Methods and Protocols
Conducting polymers and applications
article

Studies on Square Wave and Cyclic Voltammetric Behavior of 1,2- and 1,4-Dihydroxybenzenes and Their Derivatives in Acetic Acid, Ethyl Acetate and Mixtures of the Two

László Kiss
article en

Abstract

An electrochemical investigation of 1,2- and 1,4-dihydroxybenzenes was carried out with platinum macro- and microelectrodes using square wave and cyclic voltammetry techniques. Furthermore, the effect of the two solvents-acetic acid and ethyl acetate-was compared. When using square wave voltammetry, signals only appeared at lower frequencies and only when the supporting electrolyte was in excess, as expected due to the relatively low permittivity of the used solvents. The behavior of hydroquinone and catechol did not differ significantly from that of their derivatives (dihydroxybenzaldehydes, dihydroxybenzoic acids and 2',5'-dihydroxyacetophenone). When the cyclic voltammetric experiments using a microelectrode were extended to higher anodic potentials, electrode fouling was very significant in ethyl acetate after the potential region where steady-state oxidation to the corresponding quinone occurs. The substituent effect was not significant here either, which was proven by using different functional groups in different positions. In contrast, the position had a dramatic influence on the susceptibility to electropolymerization, as 1,2-dihydroxybenzenes-independent of the nature of the substituent on the benzene ring-deactivated the electrode, while 1,4-dihydroxybenzenes did not, possibly due to the different solubilities of the polymers formed from the primary oxidation product (quinones). A user-friendly analytical procedure is also proposed that uses an electropolymerization reaction and does not require frequent cleaning of the electrode via polishing, which is required usually especially with a microelectrode.

Methods and ProtocolsVol. 7(6)
University of Pecs (HU)
Pécsi Tudományegyetem, Nemzeti Kutatási Fejlesztési és Innovációs Hivatal, Innovációs és Technológiai Minisztérium
Openalex Percentile: Top 81%
Conducting polymers and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.