Fault location on overhead power lines using multi-hypothesis sequential analysis and the Armitage algorithm

The use of modern methods for determining the fault location (FL) on overhead power lines (OHРLs), which have high accuracy and high speed, allows you to quickly find and repair damage. Various physical principles and algorithms for calculating the distance to the site of damage are used in FL OHРLs devices from different manufacturers. Some of algorithms for FL on OHРLs use the emergency mode parameters (EMP), other algorithms use measurement results based on wave methods. Many random factors that determine the magnitude of the error in calculating the distance to the FL affect the operation of FL devices by EMP. Methods based on deterministic procedures used in well-known FL devices for OHРLs do not take into account the influence of random factors, which significantly increases the time to search for the fault. The authors have developed a new method of FL on OHРLs using multi-hypothesis sequential analysis and the Armitage algorithm. The task of recognizing a faulted section of an OHРL is formulated as a statistical problem. To do this, the inspection area of the OHРL is divided into many sections, followed by the implementation of the procedure for FL. The developed method makes it possible to adapt the distortions of currents and voltages on the emergency mode oscillograms to the conditions for estimating their parameters. The results of the calculations proved that the implementation of the developed method has practically no effect on the speed of the FL algorithm for the OHРL by EMP. This ensures the uniqueness of determining the faulted section of the OHРL under the influence of random factors, which leads to a significant reduction in the inspection area of the OHРL. The application of the developed method in FL devices for OHРLs will ensure the required reliability of power supply to consumers and reduce losses from power outages by minimizing the time to search for a fault.

Authors

Institutions

Publication Details

Journal
Известия Российской академии наук Энергетика
Published
2024-12-21
DOI
https://doi.org/10.31857/s0002331024040028
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault location on overhead power lines using multi-hypothesis sequential analysis and the Armitage algorithm

А. Л. Куликов, Pavel V. ILYUSHIN, Anton Loskutov
Известия Российской академии наук Энергетика
Power Systems Fault Detection
article

Fault location on overhead power lines using multi-hypothesis sequential analysis and the Armitage algorithm

А. Л. Куликов, Pavel V. ILYUSHIN, Anton Loskutov
article en

Abstract

The use of modern methods for determining the fault location (FL) on overhead power lines (OHРLs), which have high accuracy and high speed, allows you to quickly find and repair damage. Various physical principles and algorithms for calculating the distance to the site of damage are used in FL OHРLs devices from different manufacturers. Some of algorithms for FL on OHРLs use the emergency mode parameters (EMP), other algorithms use measurement results based on wave methods. Many random factors that determine the magnitude of the error in calculating the distance to the FL affect the operation of FL devices by EMP. Methods based on deterministic procedures used in well-known FL devices for OHРLs do not take into account the influence of random factors, which significantly increases the time to search for the fault. The authors have developed a new method of FL on OHРLs using multi-hypothesis sequential analysis and the Armitage algorithm. The task of recognizing a faulted section of an OHРL is formulated as a statistical problem. To do this, the inspection area of the OHРL is divided into many sections, followed by the implementation of the procedure for FL. The developed method makes it possible to adapt the distortions of currents and voltages on the emergency mode oscillograms to the conditions for estimating their parameters. The results of the calculations proved that the implementation of the developed method has practically no effect on the speed of the FL algorithm for the OHРL by EMP. This ensures the uniqueness of determining the faulted section of the OHРL under the influence of random factors, which leads to a significant reduction in the inspection area of the OHРL. The application of the developed method in FL devices for OHРLs will ensure the required reliability of power supply to consumers and reduce losses from power outages by minimizing the time to search for a fault.

Известия Российской академии наук Энергетика(4)
Russian Academy of Sciences (RU), Nizhny Novgorod State Technical University (RU), Nizhny Novgorod State Pedagogical University (RU)
Affordable and clean energy
Openalex Percentile: Top 72%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.