Effects of selected physical parameters on the gamma-ray-induced EPR signal of glycine dosimeter

Abstract Electron paramagnetic resonance (EPR) dosimetric characteristics of glycine irradiated with a broad range of gamma doses, ranging from 0.1 Gy up to 100 kGy, were examined. Further physical parameters were investigated, such as irradiation temperature, dose fractionation, fading for different isothermal annealing temperatures, and UV exposure. The gamma dose response of glycine represents ~ 36% of that of alanine at a gamma dose of 5 kGy, and this ratio decreases as the gamma dose increases. The calculated detection limit is about 130 mGy. There is no significant variation in the EPR intensity of exposed glycine due to the change in the intermediate intervals between the two fractions. The optimum annealing temperature and duration time overcoming the fading impact for immediate readout of glycine after irradiation were found to be 110 °C for 15 min. UVC induces a broad peak in the unirradiated glycine sample at the same position that overlaps with the dosimetric peak of gamma rays. Keeping the glycine dosimeter in the dark is recommended to prevent the UV effect.

Authors

Institutions

Publication Details

Journal
The European Physical Journal Plus
Published
2024-12-20
DOI
https://doi.org/10.1140/epjp/s13360-024-05876-8
Citations
2
Primary Topic
Radiation Effects and Dosimetry
Type
article
Field-Weighted Citation Impact
0.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of selected physical parameters on the gamma-ray-induced EPR signal of glycine dosimeter

E. Aboelezz, M.A. Sharaf
2 citations
The European Physical Journal Plus
Radiation Effects and Dosimetry
0.70
article

Effects of selected physical parameters on the gamma-ray-induced EPR signal of glycine dosimeter

E. Aboelezz, M.A. Sharaf
article en
2 citations

Abstract

Abstract Electron paramagnetic resonance (EPR) dosimetric characteristics of glycine irradiated with a broad range of gamma doses, ranging from 0.1 Gy up to 100 kGy, were examined. Further physical parameters were investigated, such as irradiation temperature, dose fractionation, fading for different isothermal annealing temperatures, and UV exposure. The gamma dose response of glycine represents ~ 36% of that of alanine at a gamma dose of 5 kGy, and this ratio decreases as the gamma dose increases. The calculated detection limit is about 130 mGy. There is no significant variation in the EPR intensity of exposed glycine due to the change in the intermediate intervals between the two fractions. The optimum annealing temperature and duration time overcoming the fading impact for immediate readout of glycine after irradiation were found to be 110 °C for 15 min. UVC induces a broad peak in the unirradiated glycine sample at the same position that overlaps with the dosimetric peak of gamma rays. Keeping the glycine dosimeter in the dark is recommended to prevent the UV effect.

The European Physical Journal PlusVol. 139(12)
National Institute of Standards (EG)
Science and Technology Development Fund
Openalex Percentile: Top 26%
Radiation Effects and Dosimetry
0.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effects of selected physical parameters on the gamma-ray-induced EPR signal of glycine dosimeter — E. Aboelezz, M.A. Sharaf · The European Physical Journal Plus (2024) | TGRS Research Map | TGRS