Extracting Biomedical Signals from High Noise Environments

Modern measurement systems must have the ability to perform measurements in high-level noise environments. The field with a particularly high content of noise is biomedicine. The traditional approach to solving this problem is to inject very high energy signals in order to minimize the impact of noise on the measurement (Magnetic resonance imaging, X-rays). Unfortunately, this means that these systems are very large, expensive, difficult to maintain and often contain toxic materials. This paper presents research aimed at finding a non-invasive method that uses low-intensity signals that are completely harmless to humans, and at the same time allows extracting the measured signal from a highly noised environment. Noise suppression was achieved with a lock-in amplifier.

Authors

Institutions

Publication Details

Journal
Fluctuation and Noise Letters
Published
2024-12-20
DOI
https://doi.org/10.1142/s0219477524400686
Primary Topic
Phonocardiography and Auscultation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extracting Biomedical Signals from High Noise Environments

Bojan Kuljić, Péter Odry
Fluctuation and Noise Letters
Phonocardiography and Auscultation Techniques
article

Extracting Biomedical Signals from High Noise Environments

Bojan Kuljić, Péter Odry
article en

Abstract

Modern measurement systems must have the ability to perform measurements in high-level noise environments. The field with a particularly high content of noise is biomedicine. The traditional approach to solving this problem is to inject very high energy signals in order to minimize the impact of noise on the measurement (Magnetic resonance imaging, X-rays). Unfortunately, this means that these systems are very large, expensive, difficult to maintain and often contain toxic materials. This paper presents research aimed at finding a non-invasive method that uses low-intensity signals that are completely harmless to humans, and at the same time allows extracting the measured signal from a highly noised environment. Noise suppression was achieved with a lock-in amplifier.

Fluctuation and Noise LettersVol. 24(01)
Technical College of Applied Sciences (RS), University of Dunaújváros (HU)
Openalex Percentile: Top 57%
Phonocardiography and Auscultation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.