Design and Simulation of Three Zones Distance Protection Scheme

This work describes the protection mechanism of transmission line at fault. Transmission line is divided into three zones and it is also provided by a backup protection MATLAB simulation was used to represent the three steps protection under single line to ground fault in different zones. Distance Relay was used to measure impedance as a part of power system, when the fault impedance dropped below the predetermined value a trip signal will transmit to the circuit breaker. MATLAB simulation is used to simulate the proposed model for three zones. The results illustrated the fault impedance at each zone and finally it has been concluded that the lower impedance is obtained at zone B (27.33 ?) in phase T.

Authors

Institutions

Publication Details

Journal
NTU Journal of Engineering and Technology
Published
2024-12-20
DOI
https://doi.org/10.56286/ntujet.v3i4.1064
Primary Topic
Wireless Sensor Networks and IoT
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Simulation of Three Zones Distance Protection Scheme

Ali N. Hamoodi, Kamal Mohammed Mejdhab
NTU Journal of Engineering and Technology
Wireless Sensor Networks and IoT
article

Design and Simulation of Three Zones Distance Protection Scheme

Ali N. Hamoodi, Kamal Mohammed Mejdhab
article en

Abstract

This work describes the protection mechanism of transmission line at fault. Transmission line is divided into three zones and it is also provided by a backup protection MATLAB simulation was used to represent the three steps protection under single line to ground fault in different zones. Distance Relay was used to measure impedance as a part of power system, when the fault impedance dropped below the predetermined value a trip signal will transmit to the circuit breaker. MATLAB simulation is used to simulate the proposed model for three zones. The results illustrated the fault impedance at each zone and finally it has been concluded that the lower impedance is obtained at zone B (27.33 ?) in phase T.

NTU Journal of Engineering and TechnologyVol. 3(4)
Northern Technical University (IQ)
Sustainable cities and communities
Openalex Percentile: Top 72%
Wireless Sensor Networks and IoT
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Simulation of Three Zones Distance Protection Scheme — Ali N. Hamoodi, Kamal Mohammed Mejdhab · NTU Journal of Engineering and Technology (2024) | TGRS Research Map | TGRS