Effect of Central Corneal Thickness on Intra Ocular Pressure Measured by NCT and GAT

Purpose: To assess the effect of central corneal thickness (CCT) on intra ocular pressure measured by non-contact tonometer and goldmann applanation tonometer. Method: A hospital based observational study done on 60 eyes of 30 patients aged 18-40 years, without comorbidities and without history of ocular trauma. CCT was measured first using Tomey Specular microscope EM-4000, NCT (non-contact tonometer) using air puff Frey TN-100, followed by GAT (goldmann applanation tonometer). Results: Pearson Correlation:0.59 (p-value < 0.001), indicates a moderate positive correlation, confirming that higher CCT is associated with higher GAT readings. Linear Regression: Slope of 0.12 and R-squared of 0.35, suggests that about 35% of the variability in GAT readings is explained by CCT. Pearson Correlation: 0.84 (p-value < 0.001), indicating a strong positive correlation indicating a strong association between higher CCT and higher NCT readings. Linear Regression: Slope of 0.24 and R-squared of 0.71, shows that 71% of the variability in NCT readings can be explained by CCT. CCT significantly impacts both GAT and NCT readings, with NCT readings being more strongly affected by changes in CCT.

Authors

Publication Details

Journal
International Journal of Science and Research (IJSR)
Published
2024-12-20
DOI
https://doi.org/10.21275/sr241218165256
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Central Corneal Thickness on Intra Ocular Pressure Measured by NCT and GAT

T M Nithisha, Kolari S. Bhat, Mayuri Kathariya
International Journal of Science and Research (IJSR)
Corneal surgery and disorders
article

Effect of Central Corneal Thickness on Intra Ocular Pressure Measured by NCT and GAT

T M Nithisha, Kolari S. Bhat, Mayuri Kathariya
article en

Abstract

Purpose: To assess the effect of central corneal thickness (CCT) on intra ocular pressure measured by non-contact tonometer and goldmann applanation tonometer. Method: A hospital based observational study done on 60 eyes of 30 patients aged 18-40 years, without comorbidities and without history of ocular trauma. CCT was measured first using Tomey Specular microscope EM-4000, NCT (non-contact tonometer) using air puff Frey TN-100, followed by GAT (goldmann applanation tonometer). Results: Pearson Correlation:0.59 (p-value < 0.001), indicates a moderate positive correlation, confirming that higher CCT is associated with higher GAT readings. Linear Regression: Slope of 0.12 and R-squared of 0.35, suggests that about 35% of the variability in GAT readings is explained by CCT. Pearson Correlation: 0.84 (p-value < 0.001), indicating a strong positive correlation indicating a strong association between higher CCT and higher NCT readings. Linear Regression: Slope of 0.24 and R-squared of 0.71, shows that 71% of the variability in NCT readings can be explained by CCT. CCT significantly impacts both GAT and NCT readings, with NCT readings being more strongly affected by changes in CCT.

International Journal of Science and Research (IJSR)Vol. 13(12)
Openalex Percentile: Top 59%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Central Corneal Thickness on Intra Ocular Pressure Measured by NCT and GAT — T M Nithisha, Kolari S. Bhat, et al. · International Journal of Science and Research (IJSR) (2024) | TGRS Research Map | TGRS