Galvanic Isolation Circuit for the Interoperation of Semiconductor and Tube Systems in a Missile Guidance Station

The article presents a practical solution for a galvanic isolation circuit designed to ensure the interoperability of systems within the fire control radar of the S-200 air defence system. Galvanic isolation safeguards semiconductor systems by mitigating the impact of high-amplitude return signals commonly encountered in controlled tube systems, as well as suppressing electromagnetic interference that may propagate along transmission lines. Based on the assembly measurements, it can be concluded that the amplifier controlling the tube system provides the required signal amplitude level in the frequency range from fractions of Hz to several kHz. Additionally, the amplifier for the semiconductor system, connected via the transmission line, achieves the required offset voltage and signal amplitude levels across a frequency range from several dozen Hz to several hundred kHz.

Authors

Institutions

Publication Details

Journal
Problems of Mechatronics Armament Aviation Safety Engineering
Published
2024-12-20
DOI
https://doi.org/10.5604/01.3001.0054.9130
Primary Topic
Infrared Target Detection Methodologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Galvanic Isolation Circuit for the Interoperation of Semiconductor and Tube Systems in a Missile Guidance Station

Stanisław Żygadło, Stanisław Grzywiński
Problems of Mechatronics Armament Aviation Safety Engineering
Infrared Target Detection Methodologies
article

Galvanic Isolation Circuit for the Interoperation of Semiconductor and Tube Systems in a Missile Guidance Station

Stanisław Żygadło, Stanisław Grzywiński
article en

Abstract

The article presents a practical solution for a galvanic isolation circuit designed to ensure the interoperability of systems within the fire control radar of the S-200 air defence system. Galvanic isolation safeguards semiconductor systems by mitigating the impact of high-amplitude return signals commonly encountered in controlled tube systems, as well as suppressing electromagnetic interference that may propagate along transmission lines. Based on the assembly measurements, it can be concluded that the amplifier controlling the tube system provides the required signal amplitude level in the frequency range from fractions of Hz to several kHz. Additionally, the amplifier for the semiconductor system, connected via the transmission line, achieves the required offset voltage and signal amplitude levels across a frequency range from several dozen Hz to several hundred kHz.

Problems of Mechatronics Armament Aviation Safety EngineeringVol. 15(4)
Military University of Technology in Warsaw (PL)
Openalex Percentile: Top 61%
Infrared Target Detection Methodologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.