Hollow Fiber Microreactor Combined with Digital Twin to Optimize the Antimicrobial Evaluation Process

In order to reproduce pharmacokinetics (PK) profiles seen in vivo, the Hollow Fiber Infection Model (HFIM) is a useful in vitro module in the evaluation of antimicrobial resistance. In order to reduce the consumption of culture medium and drugs, we developed a hollow fiber microreactor applicable to the HFIM by integrating the HFIM function. Next, we constructed a novel control method by using the "digital twin" of the microreactor to achieve precise concentration control. By integrating functions of the HFIM, the extra-capillary space volume was reduced to less than 1/10 of conventional HFIM. The control method with the digital twin can keep drug concentration in the extra-capillary space within an error of 10% under simulated drug destruction. The control method with the digital twin can also stabilize the drug concentration both in the intra-capillary space and the extra-capillary space within 15 min.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2024-12-20
DOI
https://doi.org/10.3390/mi15121517
Citations
1
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hollow Fiber Microreactor Combined with Digital Twin to Optimize the Antimicrobial Evaluation Process

Madoka Takai, Masakaze Hamada, Ryo Miyake, Toshihiro Kasama et al.
1 citations
Micromachines
Innovative Microfluidic and Catalytic Techniques Innovation
0.18
article

Hollow Fiber Microreactor Combined with Digital Twin to Optimize the Antimicrobial Evaluation Process

Madoka Takai, Masakaze Hamada, Ryo Miyake, Toshihiro Kasama, Yukiko T. Matsunaga, Marie Shinohara, Yoshikazu Ishii, Kazuhiro Noda
article en
1 citations

Abstract

In order to reproduce pharmacokinetics (PK) profiles seen in vivo, the Hollow Fiber Infection Model (HFIM) is a useful in vitro module in the evaluation of antimicrobial resistance. In order to reduce the consumption of culture medium and drugs, we developed a hollow fiber microreactor applicable to the HFIM by integrating the HFIM function. Next, we constructed a novel control method by using the "digital twin" of the microreactor to achieve precise concentration control. By integrating functions of the HFIM, the extra-capillary space volume was reduced to less than 1/10 of conventional HFIM. The control method with the digital twin can keep drug concentration in the extra-capillary space within an error of 10% under simulated drug destruction. The control method with the digital twin can also stabilize the drug concentration both in the intra-capillary space and the extra-capillary space within 15 min.

MicromachinesVol. 15(12)
Toho University (JP), The University of Tokyo (JP)
Japan Agency for Medical Research and Development
Good health and well-being
Openalex Percentile: Top 49%
Innovative Microfluidic and Catalytic Techniques Innovation
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Hollow Fiber Microreactor Combined with Digital Twin to Optimize the Antimicrobial Evaluation Process — Madoka Takai, Masakaze Hamada, et al. · Micromachines (2024) | TGRS Research Map | TGRS