Reliability Study of Weight-Bearing Upper Extremity Sway Test Performed on a Force Plate in the One-Handed Plank Position

(1) Background: The aim of this study is to determine the intra-rater and test–retest reliability of an upper extremity sway test performed in the one-handed plank position on a force plate and to establish if there are any between-limb differences in assessment with either open or closed eyes. (2) Methods: Fifteen males participated in this study (23.1 ± 2.3 years; 71.2 ± 7.4 kg; 175 ± 4 cm). The sway test (ST) on the force plate was performed during two separate visits, with a one-week interval between tests performed with eyes open and closed, separately for the left and right upper limbs. (3) Results: Intra-rater reliability for measurements with eyes open and closed on both the left and right sides was good to excellent for almost all variables (ICC = 0.84–0.96). Moderate reliability was observed only for the center of pressure (COP) area. Test–retest reliability was somewhat lower. With eyes open and closed, good to excellent reliability was observed for COP length and velocity in the M-L direction and for the total COP length (ICC = 0.77–0.95). However, for COP length and velocity in the A-P direction, as well as for COP area, reliability was moderate (ICC = 0.58–0.70). No significant differences were found between the left and right sides in any variable. (4) Conclusions: The results of this study indicate that the upper limb sway test performed on a force plate in the one-handed plank position, both with eyes open and closed, is a reliable measurement option and has practical applications in clinical settings, including for baseline assessments, return-to-play protocols, and injury prevention strategies.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-12-20
DOI
https://doi.org/10.3390/app142411945
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability Study of Weight-Bearing Upper Extremity Sway Test Performed on a Force Plate in the One-Handed Plank Position

Jarosław Witkowski, Joanna Zyznawska, Grzegorz Bril, J Deszczyński et al.
Applied Sciences
Muscle activation and electromyography studies
article

Reliability Study of Weight-Bearing Upper Extremity Sway Test Performed on a Force Plate in the One-Handed Plank Position

Jarosław Witkowski, Joanna Zyznawska, Grzegorz Bril, J Deszczyński, Maciej Kuchciak, Zofia Dzięcioł-Anikiej, Martyna Sopa, Artur Stolarczyk, Olga Adamska, Łukasz Oleksy, Anna Mika, Renata Kielnar
article en

Abstract

(1) Background: The aim of this study is to determine the intra-rater and test–retest reliability of an upper extremity sway test performed in the one-handed plank position on a force plate and to establish if there are any between-limb differences in assessment with either open or closed eyes. (2) Methods: Fifteen males participated in this study (23.1 ± 2.3 years; 71.2 ± 7.4 kg; 175 ± 4 cm). The sway test (ST) on the force plate was performed during two separate visits, with a one-week interval between tests performed with eyes open and closed, separately for the left and right upper limbs. (3) Results: Intra-rater reliability for measurements with eyes open and closed on both the left and right sides was good to excellent for almost all variables (ICC = 0.84–0.96). Moderate reliability was observed only for the center of pressure (COP) area. Test–retest reliability was somewhat lower. With eyes open and closed, good to excellent reliability was observed for COP length and velocity in the M-L direction and for the total COP length (ICC = 0.77–0.95). However, for COP length and velocity in the A-P direction, as well as for COP area, reliability was moderate (ICC = 0.58–0.70). No significant differences were found between the left and right sides in any variable. (4) Conclusions: The results of this study indicate that the upper limb sway test performed on a force plate in the one-handed plank position, both with eyes open and closed, is a reliable measurement option and has practical applications in clinical settings, including for baseline assessments, return-to-play protocols, and injury prevention strategies.

Applied SciencesVol. 14(24)
Rzeszów University of Technology (PL), Jagiellonian University (PL), Medical University of Białystok (PL), University School of Physical Education in Kraków (PL), Medical University of Warsaw (PL), Wroclaw Medical University (PL), Poznań University of Technology (PL), Cardinal Stefan Wyszynski University in Warsaw (PL), University of Rzeszów (PL)
Good health and well-being
Openalex Percentile: Top 78%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.