Combining Optical Sensing with Deep Learning for Enhanced Non-Invasive Kidney Function Measurement

The difficulty of non-invasive kidney function monitoring is addressed in the paper by using a deep learning model that uses optical sensors to estimate Glomerular Filtration Rate (GFR). The model showed impressive performance by predicting GFR with a Mean Absolute Error (MAE) of 2.3. It also registered 0.84 F1 Score, 0.78 precision, 0.92 recall, and 0.85 accuracy. These measurements demonstrate how well the model divides renal disease and predicts GFR. With an accuracy of less than $\mathbf{5 0 \%}$ and an MAE of 4.7, the proposed method significantly outperforms the baseline technique. Furthermore, the model outperforms earlier methods in terms of accuracy and precision, as shown by a comparison with earlier studies. The findings support the strong efficacy of the suggested approach in offering a trustworthy, non-invasive substitute for evaluating kidney health, with possible clinical setting applicability.

Authors

Institutions

Publication Details

Published
2024-10-18
DOI
https://doi.org/10.1109/ssitcon62437.2024.10796304
Primary Topic
Renal and Vascular Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combining Optical Sensing with Deep Learning for Enhanced Non-Invasive Kidney Function Measurement

G. Divya, Vasuki Rajaguru
Renal and Vascular Pathologies
article

Combining Optical Sensing with Deep Learning for Enhanced Non-Invasive Kidney Function Measurement

G. Divya, Vasuki Rajaguru
article en

Abstract

The difficulty of non-invasive kidney function monitoring is addressed in the paper by using a deep learning model that uses optical sensors to estimate Glomerular Filtration Rate (GFR). The model showed impressive performance by predicting GFR with a Mean Absolute Error (MAE) of 2.3. It also registered 0.84 F1 Score, 0.78 precision, 0.92 recall, and 0.85 accuracy. These measurements demonstrate how well the model divides renal disease and predicts GFR. With an accuracy of less than $\mathbf{5 0 \%}$ and an MAE of 4.7, the proposed method significantly outperforms the baseline technique. Furthermore, the model outperforms earlier methods in terms of accuracy and precision, as shown by a comparison with earlier studies. The findings support the strong efficacy of the suggested approach in offering a trustworthy, non-invasive substitute for evaluating kidney health, with possible clinical setting applicability.

Bharath University (IN)
Zero hunger
Openalex Percentile: Top 57%
Renal and Vascular Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Combining Optical Sensing with Deep Learning for Enhanced Non-Invasive Kidney Function Measurement — G. Divya, Vasuki Rajaguru · (2024) | TGRS Research Map | TGRS