A Nonuniform Sampling Lifetime Estimation Technique for Luminescent Oxygen Measurements for Biomedical Applications

This article presents a novel technique that is immune to offset, enabling precise determination of the lifetime of luminescent materials. The technique is specifically applied to measure transcutaneous oxygen, an indicator of oxygen that diffuses through the skin and reflects arterial oxygen levels. Unlike intensity-based measurements, lifetime-based luminescence measurements are superior because they decouple oxygen information from confounding factors. The technique presented in this work involves measuring the time difference between fixed-voltage steps to extract the time constant of a decaying exponential, which represents the lifetime of luminescence. We propose a novel switched-capacitor circuit that enables long integration times and prevents the front-end amplifier from saturating. The analog subsystem was realized in 180-nm CMOS technology via a transimpedance amplifier (TIA) with a gain bandwidth product of 10 MHz, a comparator, and a switched capacitor circuit. The measured mean error is as accurate as 1.9% without postprocessing. During a 130 <i>μ</i>s measurement period, the readout circuit consumes a maximum of 16 <i>μ</i>J per calculation with a <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub><mml:mrow><mml:mtext>FoM</mml:mtext></mml:mrow> <mml:mrow><mml:mi>W</mml:mi></mml:mrow> </mml:msub> <mml:mo>=</mml:mo> <mml:mn>177</mml:mn> <mml:mspace></mml:mspace> <mml:mtext>nJ</mml:mtext> <mml:mo>/</mml:mo> <mml:mtext>conv</mml:mtext></mml:math> . Preliminary human subject tests have demonstrated that the sensor can effectively detect changes in transcutaneous oxygen levels resulting from arterial occlusion.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Solid-State Circuits
Published
2024-12-20
DOI
https://doi.org/10.1109/jssc.2024.3512472
Citations
3
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Nonuniform Sampling Lifetime Estimation Technique for Luminescent Oxygen Measurements for Biomedical Applications

John McNeill, Ülkühan Güler, Devdip Sen, Ian Costanzo
3 citations
IEEE Journal of Solid-State Circuits
Analytical Chemistry and Sensors
0.87
article

A Nonuniform Sampling Lifetime Estimation Technique for Luminescent Oxygen Measurements for Biomedical Applications

John McNeill, Ülkühan Güler, Devdip Sen, Ian Costanzo
article en
3 citations

Abstract

This article presents a novel technique that is immune to offset, enabling precise determination of the lifetime of luminescent materials. The technique is specifically applied to measure transcutaneous oxygen, an indicator of oxygen that diffuses through the skin and reflects arterial oxygen levels. Unlike intensity-based measurements, lifetime-based luminescence measurements are superior because they decouple oxygen information from confounding factors. The technique presented in this work involves measuring the time difference between fixed-voltage steps to extract the time constant of a decaying exponential, which represents the lifetime of luminescence. We propose a novel switched-capacitor circuit that enables long integration times and prevents the front-end amplifier from saturating. The analog subsystem was realized in 180-nm CMOS technology via a transimpedance amplifier (TIA) with a gain bandwidth product of 10 MHz, a comparator, and a switched capacitor circuit. The measured mean error is as accurate as 1.9% without postprocessing. During a 130 <i>μ</i>s measurement period, the readout circuit consumes a maximum of 16 <i>μ</i>J per calculation with a <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub><mml:mrow><mml:mtext>FoM</mml:mtext></mml:mrow> <mml:mrow><mml:mi>W</mml:mi></mml:mrow> </mml:msub> <mml:mo>=</mml:mo> <mml:mn>177</mml:mn> <mml:mspace></mml:mspace> <mml:mtext>nJ</mml:mtext> <mml:mo>/</mml:mo> <mml:mtext>conv</mml:mtext></mml:math> . Preliminary human subject tests have demonstrated that the sensor can effectively detect changes in transcutaneous oxygen levels resulting from arterial occlusion.

IEEE Journal of Solid-State CircuitsVol. 60(8)
Worcester Polytechnic Institute (US)
National Science Foundation
Openalex Percentile: Top 28%
Analytical Chemistry and Sensors
0.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Nonuniform Sampling Lifetime Estimation Technique for Luminescent Oxygen Measurements for Biomedical Applications — John McNeill, Ülkühan Güler, et al. · IEEE Journal of Solid-State Circuits (2024) | TGRS Research Map | TGRS