Approaching the standard quantum limit of a Rydberg-atom microwave electrometer

The development of a microwave electrometer with inherent uncertainty approaching its ultimate limit carries both fundamental and technological significance. However, because of the thermal motion of atoms, the state-of-art Rydberg electrometer falls considerably short of the standard quantum limit by about three orders of magnitude. Here, we use an optically thin medium with approximately 5.2 × 10<sup>5</sup> laser-cooled atoms to implement the microwave heterodyne detection. By mitigating various noises and strategically optimizing the electrometer parameters, our study reduces the equivalent noise temperature by a factor of 20 and achieves an electric field sensitivity of 10.0 nV cm<sup>-1</sup> Hz<sup>-1/2</sup>, lastly reaching a factor of 2.6 above the standard quantum limit. Our work also provides valuable insights into the inherent capabilities and limitations of Rydberg electrometers, offering superior sensitivity in detecting weak microwave signals for numerous applications.

Authors

Institutions

Publication Details

Journal
Science Advances
Published
2024-12-20
DOI
https://doi.org/10.1126/sciadv.ads0683
Citations
22
Primary Topic
Cold Atom Physics and Bose-Einstein Condensates
Type
article
Field-Weighted Citation Impact
7.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Approaching the standard quantum limit of a Rydberg-atom microwave electrometer

Shi-Liang Zhu, Hai-Tao Tu, Kai-Yu Liao, Hao Jiang et al.
22 citations
Science Advances
Cold Atom Physics and Bose-Einstein Condensates
7.43
article

Approaching the standard quantum limit of a Rydberg-atom microwave electrometer

Shi-Liang Zhu, Hai-Tao Tu, Kai-Yu Liao, Hao Jiang, Bian Wu, Hong-Lei Wang, Hui Yan, Yifei Zhu, Wei Huang, Siyuan Qiu
article en
22 citations

Abstract

The development of a microwave electrometer with inherent uncertainty approaching its ultimate limit carries both fundamental and technological significance. However, because of the thermal motion of atoms, the state-of-art Rydberg electrometer falls considerably short of the standard quantum limit by about three orders of magnitude. Here, we use an optically thin medium with approximately 5.2 × 10<sup>5</sup> laser-cooled atoms to implement the microwave heterodyne detection. By mitigating various noises and strategically optimizing the electrometer parameters, our study reduces the equivalent noise temperature by a factor of 20 and achieves an electric field sensitivity of 10.0 nV cm<sup>-1</sup> Hz<sup>-1/2</sup>, lastly reaching a factor of 2.6 above the standard quantum limit. Our work also provides valuable insights into the inherent capabilities and limitations of Rydberg electrometers, offering superior sensitivity in detecting weak microwave signals for numerous applications.

Science AdvancesVol. 10(51)
South China Normal University (CN), Quantum Science Center of Guangdong-Hong Kong-Macao Greater Bay Area (CN)
National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province
Affordable and clean energy
Openalex Percentile: Top 2%
Cold Atom Physics and Bose-Einstein Condensates
7.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.