Comparison of clinical results between transpulmonary thermodilution monitoring and conventional methods in cardiac surgery: An observational study

The Pulse Index Contour Continuous Cardiac Output (PICCO) module provides advanced and continuous monitoring of cardiac output through the use of arterial pulse contour analysis and transpulmonary thermodilution. The objective of this study was to compare the early postoperative outcomes of patients who were monitored using the conventional method and the pulse contour analysis method. A prospective observational study was conducted involving 45 patients who underwent cardiac surgery between 2020 and 2022. Patients were randomly assigned to either Group P (PICCO) or Group C (conventional). In the PICCO cohort, a femoral artery cannula was inserted for the continuous recording and management of hemodynamic data, in accordance with the decision-making algorithm of the module. In the conventional group, cannulation of the radial artery and jugular vein was performed. The postoperative hemodynamic and clinical data are subjected to analysis. The utilization of dopamine was markedly diminished in Group P at both the 0- and 6-hour postoperative intervals, whereas the administration of dobutamine was observed to be elevated (P = .008). The frequency of red packed cell transfusions was higher in Group C at postoperative hour 0. Hemodynamic data indicated a 42% increase in cardiac index and a 33% decrease in systemic vascular resistance, along with a 33% increase in global ejection fraction in patients monitored with PICCO. The mortality rates observed in the 2 groups were not statistically different. The implementation of advanced monitoring techniques, specifically the PICCO module, led to notable enhancements in hemodynamic parameters. The utilization of this technique may prove advantageous in guiding inotrope selection and transfusion decisions during the initial postoperative period. However, it is important to note that morbidity and mortality rates remain comparable.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2024-12-20
DOI
https://doi.org/10.1097/md.0000000000040884
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of clinical results between transpulmonary thermodilution monitoring and conventional methods in cardiac surgery: An observational study

Pelin Öztürk, Osman Nuri Tuncer, Seden Kocabaş, Emre Demir et al.
Medicine
Hemodynamic Monitoring and Therapy
article

Comparison of clinical results between transpulmonary thermodilution monitoring and conventional methods in cardiac surgery: An observational study

Pelin Öztürk, Osman Nuri Tuncer, Seden Kocabaş, Emre Demir, Ümit Kahraman, Mustafa Özbaran, Serkan Ertugay, Esin Öztürk, Emrah Oğuz
article en

Abstract

The Pulse Index Contour Continuous Cardiac Output (PICCO) module provides advanced and continuous monitoring of cardiac output through the use of arterial pulse contour analysis and transpulmonary thermodilution. The objective of this study was to compare the early postoperative outcomes of patients who were monitored using the conventional method and the pulse contour analysis method. A prospective observational study was conducted involving 45 patients who underwent cardiac surgery between 2020 and 2022. Patients were randomly assigned to either Group P (PICCO) or Group C (conventional). In the PICCO cohort, a femoral artery cannula was inserted for the continuous recording and management of hemodynamic data, in accordance with the decision-making algorithm of the module. In the conventional group, cannulation of the radial artery and jugular vein was performed. The postoperative hemodynamic and clinical data are subjected to analysis. The utilization of dopamine was markedly diminished in Group P at both the 0- and 6-hour postoperative intervals, whereas the administration of dobutamine was observed to be elevated (P = .008). The frequency of red packed cell transfusions was higher in Group C at postoperative hour 0. Hemodynamic data indicated a 42% increase in cardiac index and a 33% decrease in systemic vascular resistance, along with a 33% increase in global ejection fraction in patients monitored with PICCO. The mortality rates observed in the 2 groups were not statistically different. The implementation of advanced monitoring techniques, specifically the PICCO module, led to notable enhancements in hemodynamic parameters. The utilization of this technique may prove advantageous in guiding inotrope selection and transfusion decisions during the initial postoperative period. However, it is important to note that morbidity and mortality rates remain comparable.

MedicineVol. 103(51)
Ege University (TR)
Ege Üniversitesi
Good health and well-being
Openalex Percentile: Top 56%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.