Zeptojoule calorimetry

Abstract The measurement of energy is a fundamental tool used in quantum technology and computing. Some of the most sensitive energy detectors—bolometers and calorimeters—are thermal, meaning that they operate by absorbing incoming energy, converting it into heat and reading out the resulting temperature change electrically using a thermometer. Recently, superconductor–normal-conductor–superconductor radiation sensors with metallic and graphene absorbers haven been predicted to be capable of full-width at half-maximum energy resolutions of 0.75 zJ and 0.05 zJ, respectively. However, these estimates are only mathematically extracted from steady-state noise and responsivity measurements. Here we show that a metallic superconductor–normal-conductor–superconductor sensor can be used for zeptojoule calorimetry. With the approach, we measure the energy of 1-μs-long 8.4-GHz microwave pulses with a full-width at half-maximum energy resolution finer than 0.95 ± 0.02 zJ (=5.9 ± 0.12 meV) corresponding to 170 photons at 8.4 GHz. The technique provides a potential path to real-time calorimetric detection of single photons in the 10-GHz range.

Authors

Institutions

Publication Details

Journal
Nature Electronics
Published
2026-05-12
DOI
https://doi.org/10.1038/s41928-026-01615-2
Primary Topic
Lipid Membrane Structure and Behavior
Type
preprint
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Zeptojoule calorimetry

Kassius Kohvakka, Roope Kokkoniemi, J.P. Girard, Mikko Möttönen et al.
Nature Electronics
Lipid Membrane Structure and Behavior
preprint

Zeptojoule calorimetry

Kassius Kohvakka, Roope Kokkoniemi, J.P. Girard, Mikko Möttönen, András Gunyhó, Qiming Chen, Wei Liu
preprint en

Abstract

Abstract The measurement of energy is a fundamental tool used in quantum technology and computing. Some of the most sensitive energy detectors—bolometers and calorimeters—are thermal, meaning that they operate by absorbing incoming energy, converting it into heat and reading out the resulting temperature change electrically using a thermometer. Recently, superconductor–normal-conductor–superconductor radiation sensors with metallic and graphene absorbers haven been predicted to be capable of full-width at half-maximum energy resolutions of 0.75 zJ and 0.05 zJ, respectively. However, these estimates are only mathematically extracted from steady-state noise and responsivity measurements. Here we show that a metallic superconductor–normal-conductor–superconductor sensor can be used for zeptojoule calorimetry. With the approach, we measure the energy of 1-μs-long 8.4-GHz microwave pulses with a full-width at half-maximum energy resolution finer than 0.95 ± 0.02 zJ (=5.9 ± 0.12 meV) corresponding to 170 photons at 8.4 GHz. The technique provides a potential path to real-time calorimetric detection of single photons in the 10-GHz range.

Nature Electronics
IQM (Finland) (FI), VTT Technical Research Centre of Finland (FI), Aalto University (FI)
Suomalainen Tiedeakatemia, Aalto-Yliopisto, Suomen Kulttuurirahasto, Jane ja Aatos Erkon Säätiö, Teknologiateollisuuden 100-Vuotisjuhlasäätiö, Business Finland, HORIZON EUROPE Framework Programme
Openalex Percentile: Top 100%
Lipid Membrane Structure and Behavior
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.