Measurement of nitrogen leakage by Raman Lidar for observation inside the Fukushima No.1 reactor building

In the Fukushima Daiichi nuclear power plant accident, hydrogen gas was generated by the reaction of nuclear fuel with water, which caused an explosion and radioactive leakage. To prevent a recurrence, the reactor containment vessel is maintained under nitrogen gas. Lidar technology provides remote sensing with high spatial resolution. In this study, we aimed to investigate aerosol flow and nitrogen leakage using the developed compact Raman Lidar with a 355 nm 50 kHz DPSS laser. To demonstrate the system concept, we measured nitrogen gas artificially released at a flow rate of 10 NL/min at a distance of 10 m from the Lidar. The Lidar data were acquired with integration time of 20 s. Comparison of the data with and without nitrogen gas flow revealed that the system is capable of distinguishing the ambient concentration around 80% and the concentration of nearly 100% in the flow contained along the laser path inside a 1.5 m plastic tube. The reduction in oxygen concentration was also detected with another Raman channel.

Authors

Institutions

Publication Details

Published
2024-12-21
DOI
https://doi.org/10.1117/12.3042946
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of nitrogen leakage by Raman Lidar for observation inside the Fukushima No.1 reactor building

Mitsuru Ishii, Tatsuo Shiina, Shinri Kurahashi, Shohei Matsuda et al.
Advanced Optical Sensing Technologies
article

Measurement of nitrogen leakage by Raman Lidar for observation inside the Fukushima No.1 reactor building

Mitsuru Ishii, Tatsuo Shiina, Shinri Kurahashi, Shohei Matsuda, Toshihiro Somekawa, Hiroaki Kuze
article en

Abstract

In the Fukushima Daiichi nuclear power plant accident, hydrogen gas was generated by the reaction of nuclear fuel with water, which caused an explosion and radioactive leakage. To prevent a recurrence, the reactor containment vessel is maintained under nitrogen gas. Lidar technology provides remote sensing with high spatial resolution. In this study, we aimed to investigate aerosol flow and nitrogen leakage using the developed compact Raman Lidar with a 355 nm 50 kHz DPSS laser. To demonstrate the system concept, we measured nitrogen gas artificially released at a flow rate of 10 NL/min at a distance of 10 m from the Lidar. The Lidar data were acquired with integration time of 20 s. Comparison of the data with and without nitrogen gas flow revealed that the system is capable of distinguishing the ambient concentration around 80% and the concentration of nearly 100% in the flow contained along the laser path inside a 1.5 m plastic tube. The reduction in oxygen concentration was also detected with another Raman channel.

Japan Atomic Energy Agency (JP), Chiba University (JP), Institute for Laser Technology (JP)
Openalex Percentile: Top 81%
Advanced Optical Sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.