Planning and Analysis of a Hospital Building using the Developed Fibre Reinforced Concrete

This study investigates the incorporation of nylon and coir fibres in concrete to improve its performance for hospital building design. Nylon fibres were added at 0.5%, 0.75%, and 1% by volume, demonstrating notable improvements in tensile strength and reduced crack formation, particularly at the 0.75% dosage. This enhancement is crucial for meeting the structural integrity and durability requirements of healthcare facilities, where safety and resilience are paramount. Coir fibres were introduced at 1%, 2%, and 3%, effectively increasing the ductility and energy absorption characteristics of the concrete. The optimal performance was observed at the 2% dosage, which not only contributed to better structural performance but also promoted sustainability through the use of natural fibres. Overall, the synergistic effects of both nylon and coir fibres in concrete demonstrate their potential to significantly enhance the mechanical properties and longevity of materials used in the construction of hospitals, supporting the need for innovative and durable building solutions in healthcare environments.

Authors

Publication Details

Journal
International Journal For Multidisciplinary Research
Published
2024-12-17
DOI
https://doi.org/10.36948/ijfmr.2024.v06i06.33101
Primary Topic
BIM and Construction Integration
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Planning and Analysis of a Hospital Building using the Developed Fibre Reinforced Concrete

Nayana N. Patil, Sachin Janai -
International Journal For Multidisciplinary Research
BIM and Construction Integration
article

Planning and Analysis of a Hospital Building using the Developed Fibre Reinforced Concrete

Nayana N. Patil, Sachin Janai -
article en

Abstract

This study investigates the incorporation of nylon and coir fibres in concrete to improve its performance for hospital building design. Nylon fibres were added at 0.5%, 0.75%, and 1% by volume, demonstrating notable improvements in tensile strength and reduced crack formation, particularly at the 0.75% dosage. This enhancement is crucial for meeting the structural integrity and durability requirements of healthcare facilities, where safety and resilience are paramount. Coir fibres were introduced at 1%, 2%, and 3%, effectively increasing the ductility and energy absorption characteristics of the concrete. The optimal performance was observed at the 2% dosage, which not only contributed to better structural performance but also promoted sustainability through the use of natural fibres. Overall, the synergistic effects of both nylon and coir fibres in concrete demonstrate their potential to significantly enhance the mechanical properties and longevity of materials used in the construction of hospitals, supporting the need for innovative and durable building solutions in healthcare environments.

International Journal For Multidisciplinary ResearchVol. 6(6)
Openalex Percentile: Top 74%
BIM and Construction Integration
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Planning and Analysis of a Hospital Building using the Developed Fibre Reinforced Concrete — Nayana N. Patil, Sachin Janai - · International Journal For Multidisciplinary Research (2024) | TGRS Research Map | TGRS