Sensitive Determination of Bisphenol A In Urine Using Automated Solid-Phase Extraction Followed by LC-MS/MS Analysis: Application to a Human Biomonitoring Study in Brazil

Bisphenol A (BPA), an endocrine disruptor present mostly in polycarbonate plastics and epoxy resins, can migrate into food and beverages, resulting in human exposure. This study aimed to develop and validate an improved liquid chromatography-tandem mass spectroscopy (LC-MS/MS) method for measuring BPA levels in urine, applying this method for BPA exposure evaluation in a Brazilian cohort, along with BPA hair levels. Samples from 100 volunteers were collected. Urine samples were extracted using an automated solid-phase extraction procedure. The assay had a 6.5-min run time, a linear range of 0.10-25 ng mL-1, precision of 3.8-18.1%, and accuracy of 96.6-103.4%. BPA was detected in all tested urine samples (median 0.86 ng mL-1). In hair, 47% of samples had detectable BPA concentrations (median 4.8 ng g-1). No correlation was found between BPA levels in urine and hair. All levels were below the safety threshold, indicating minimal risk for the studied population, with higher urinary BPA linked to canned product consumption and higher hair levels to a healthier diet.

Authors

Publication Details

Journal
Journal of the Brazilian Chemical Society
Published
2024-12-20
DOI
https://doi.org/10.21577/0103-5053.20240226
Citations
2
Primary Topic
Effects and risks of endocrine disrupting chemicals
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitive Determination of Bisphenol A In Urine Using Automated Solid-Phase Extraction Followed by LC-MS/MS Analysis: Application to a Human Biomonitoring Study in Brazil

Roberta Zilles Hahn, Marcos Frank Bastiani, Giovana Piva Peteffi, Marina Venzon Antunes et al.
2 citations
Journal of the Brazilian Chemical Society
Effects and risks of endocrine disrupting chemicals
0.63
article

Sensitive Determination of Bisphenol A In Urine Using Automated Solid-Phase Extraction Followed by LC-MS/MS Analysis: Application to a Human Biomonitoring Study in Brazil

Roberta Zilles Hahn, Marcos Frank Bastiani, Giovana Piva Peteffi, Marina Venzon Antunes, Rafael Linden, Amanda Pacheco Bondan, Camila Favretto de Souza, P. Winter, Gianpaolo Grassi, Cloé D. Loredo, Carolina Weber Ferrareze
article en
2 citations

Abstract

Bisphenol A (BPA), an endocrine disruptor present mostly in polycarbonate plastics and epoxy resins, can migrate into food and beverages, resulting in human exposure. This study aimed to develop and validate an improved liquid chromatography-tandem mass spectroscopy (LC-MS/MS) method for measuring BPA levels in urine, applying this method for BPA exposure evaluation in a Brazilian cohort, along with BPA hair levels. Samples from 100 volunteers were collected. Urine samples were extracted using an automated solid-phase extraction procedure. The assay had a 6.5-min run time, a linear range of 0.10-25 ng mL-1, precision of 3.8-18.1%, and accuracy of 96.6-103.4%. BPA was detected in all tested urine samples (median 0.86 ng mL-1). In hair, 47% of samples had detectable BPA concentrations (median 4.8 ng g-1). No correlation was found between BPA levels in urine and hair. All levels were below the safety threshold, indicating minimal risk for the studied population, with higher urinary BPA linked to canned product consumption and higher hair levels to a healthier diet.

Journal of the Brazilian Chemical Society
Zero hunger
Openalex Percentile: Top 28%
Effects and risks of endocrine disrupting chemicals
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sensitive Determination of Bisphenol A In Urine Using Automated Solid-Phase Extraction Followed by LC-MS/MS Analysis: Application to a Human Biomonitoring Study in Brazil — Roberta Zilles Hahn, Marcos Frank Bastiani, et al. · Journal of the Brazilian Chemical Society (2024) | TGRS Research Map | TGRS