Improving localization and measurements of M-waves using high-density surface electromyography

Surface electromyography (sEMG) is useful for studying muscle function and controlling prosthetics, but cross talk from nearby muscles often limits its effectiveness. High-density surface EMG (HD-sEMG) improves spatial resolution, allowing for the isolation of M-waves in the densely packed forearm muscles. This study assessed HD-sEMG for localizing M-waves and evaluated the impact of spatial filters on cross talk reduction. We administered peripheral nerve stimulation to activate forearm muscles in five participants. We analyzed cross talk by correlating the shape of M-waves between electrodes and used ultrasound to confirm muscle identity and location. At low-stimulation intensities, we successfully isolated M-waves with minimal cross talk without spatial filtering. Higher recruitment levels produced significant cross talk, which was reduced by applying bipolar or tripolar spatial filters. M-waves from the monopolar HD-sEMG montage showed high correlations between electrodes (r = 0.97 transversely; r = 0.95 longitudinally), while bipolar and tripolar montages showed lower correlations (bipolar: r = 0.41 transversely; r = 0.19 longitudinally; tripolar: r = 0.17 transversely; r = 0.01 longitudinally). The tripolar filter significantly reduced cross talk (51.10% amplitude decay one electrode away) compared with no filter (10.32% amplitude decay one electrode away), effectively reducing cross talk to negligible levels at distances ≥2.55 cm. Ultrasound was crucial for distinguishing true activation from artifacts caused by converging signals along muscle boundaries. Spatially filtered HD-sEMG accurately detects and isolates M-waves in the forearm, and ultrasound imaging is useful for verifying the location and identity of the muscles underlying the HD-sEMG grids.<b>NEW & NOTEWORTHY</b> This study introduces an innovative approach to enhancing evoked potential measurements using high-density surface electromyography (HD-sEMG). The precision and localization of evoked potentials are significantly improved by spatial filters and ultrasound imaging, offering a novel method for better assessing motor pathway integrity. These advancements could lead to more accurate tools for detecting and treating neurological deficits, making it a significant contribution to neurophysiological research.

Authors

Institutions

Publication Details

Journal
Journal of Neurophysiology
Published
2024-12-20
DOI
https://doi.org/10.1152/jn.00354.2024
Citations
4
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving localization and measurements of M-waves using high-density surface electromyography

Estrella Díaz, Ashley N Dalrymple, George F. Wittenberg, Douglas J. Weber et al.
4 citations
Journal of Neurophysiology
Muscle activation and electromyography studies
0.74
article

Improving localization and measurements of M-waves using high-density surface electromyography

Estrella Díaz, Ashley N Dalrymple, George F. Wittenberg, Douglas J. Weber, Ernesto H. Bedoy, I. Martin Levy, Darcy M. Griffin, Thomas Hyatt
article en
4 citations

Abstract

Surface electromyography (sEMG) is useful for studying muscle function and controlling prosthetics, but cross talk from nearby muscles often limits its effectiveness. High-density surface EMG (HD-sEMG) improves spatial resolution, allowing for the isolation of M-waves in the densely packed forearm muscles. This study assessed HD-sEMG for localizing M-waves and evaluated the impact of spatial filters on cross talk reduction. We administered peripheral nerve stimulation to activate forearm muscles in five participants. We analyzed cross talk by correlating the shape of M-waves between electrodes and used ultrasound to confirm muscle identity and location. At low-stimulation intensities, we successfully isolated M-waves with minimal cross talk without spatial filtering. Higher recruitment levels produced significant cross talk, which was reduced by applying bipolar or tripolar spatial filters. M-waves from the monopolar HD-sEMG montage showed high correlations between electrodes (r = 0.97 transversely; r = 0.95 longitudinally), while bipolar and tripolar montages showed lower correlations (bipolar: r = 0.41 transversely; r = 0.19 longitudinally; tripolar: r = 0.17 transversely; r = 0.01 longitudinally). The tripolar filter significantly reduced cross talk (51.10% amplitude decay one electrode away) compared with no filter (10.32% amplitude decay one electrode away), effectively reducing cross talk to negligible levels at distances ≥2.55 cm. Ultrasound was crucial for distinguishing true activation from artifacts caused by converging signals along muscle boundaries. Spatially filtered HD-sEMG accurately detects and isolates M-waves in the forearm, and ultrasound imaging is useful for verifying the location and identity of the muscles underlying the HD-sEMG grids.<b>NEW & NOTEWORTHY</b> This study introduces an innovative approach to enhancing evoked potential measurements using high-density surface electromyography (HD-sEMG). The precision and localization of evoked potentials are significantly improved by spatial filters and ultrasound imaging, offering a novel method for better assessing motor pathway integrity. These advancements could lead to more accurate tools for detecting and treating neurological deficits, making it a significant contribution to neurophysiological research.

Journal of NeurophysiologyVol. 133(1)
University of Pittsburgh (US), University of Utah (US), Center for the Neural Basis of Cognition (US), Carnegie Mellon University (US)
Openalex Percentile: Top 31%
Muscle activation and electromyography studies
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.