Late Gadolinium Enhancement of Nonischemic Cardiomyopathy at 5.0 T versus 3.0 T: A Crossover Design Study

Purpose To compare the acquisition time, image quality, and late gadolinium enhancement (LGE) visualization and quantification on phase-sensitive inversion recovery (PSIR) images using 5.0-T versus 3.0-T cardiac MRI. Materials and Methods In this prospective crossover study, 49 participants (mean ± SD age, 43.7 years ± 13.1; 39 men) suspected or diagnosed with nonischemic cardiomyopathy were enrolled from April 2023 to March 2024 and randomly assigned to group 1 (5.0-T followed by 3.0-T LGE cardiac MRI) or group 2 (3.0-T followed by 5.0-T LGE cardiac MRI). PSIR images were acquired at spatial resolutions of 1.2, 0.9, and 1.6 mm. Image quality and LGE were qualitatively evaluated using a five-point Likert scale by two readers, and signal-to-noise ratio, contrast-to-noise ratio, and LGE mass were quantitatively assessed. Bland-Altman plots were used to evaluate interreader agreement. Results There was no evidence of a difference in the acquisition time for obtaining a single-layer PSIR image at 5.0 T compared with 3.0 T (<i>P</i> > .05 for all), irrespective of resolutions at 1.2, 0.9, and 1.6 mm. The 5.0-T PSIR images demonstrated better image quality and LGE visualization compared with 3.0-T images, particularly at 1.2 mm (image quality: median 5 [IQR, 5-5] vs median 5 [IQR, 4-5]; <i>P</i> = .004; LGE score: median 5 [IQR, 5-5] vs median 4.25 [IQR, 4-5]; <i>P</i> < .001). No evidence of differences in image quality or LGE scores was found between 5.0-T and 3.0-T cardiac MRI at 1.6-mm resolution. Signal-to-noise ratio and contrast-to-noise ratio were higher on 5.0-T PSIR images across all resolutions compared with 3.0-T images (<i>P</i> < .001 for all), but no evidence of a difference was found in LGE mass measurements. Conclusion The study demonstrates that 5.0-T PSIR imaging offers better image quality and LGE visualization than 3.0-T PSIR, particularly at a 1.2-mm resolution, in individuals with nonischemic cardiomyopathy. <b>Keywords:</b> MRI, Cardiac, Heart, Comparative Studies, Nonischemic Cardiomyopathy, Late Gadolinium Enhancement, Phase-Sensitive Inversion Recovery <i>Supplemental material is available for this article.</i> ©RSNA, 2024.

Authors

Institutions

Publication Details

Journal
Radiology Cardiothoracic Imaging
Published
2024-12-01
DOI
https://doi.org/10.1148/ryct.240035
Citations
4
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.62

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Late Gadolinium Enhancement of Nonischemic Cardiomyopathy at 5.0 T versus 3.0 T: A Crossover Design Study

Hongfei Lu, Mengsu Zeng, Yinyin Chen, Hang Jin et al.
4 citations
Radiology Cardiothoracic Imaging
Advanced MRI Techniques and Applications
1.62
article

Late Gadolinium Enhancement of Nonischemic Cardiomyopathy at 5.0 T versus 3.0 T: A Crossover Design Study

Hongfei Lu, Mengsu Zeng, Yinyin Chen, Hang Jin, Xianling Qian, Xiyin Miao, Yali Wu, Jiaxin Hao, S Zhang, Shiyu Wang, Fang Wang, Dong Wang, Rui Wang
article en
4 citations

Abstract

Purpose To compare the acquisition time, image quality, and late gadolinium enhancement (LGE) visualization and quantification on phase-sensitive inversion recovery (PSIR) images using 5.0-T versus 3.0-T cardiac MRI. Materials and Methods In this prospective crossover study, 49 participants (mean ± SD age, 43.7 years ± 13.1; 39 men) suspected or diagnosed with nonischemic cardiomyopathy were enrolled from April 2023 to March 2024 and randomly assigned to group 1 (5.0-T followed by 3.0-T LGE cardiac MRI) or group 2 (3.0-T followed by 5.0-T LGE cardiac MRI). PSIR images were acquired at spatial resolutions of 1.2, 0.9, and 1.6 mm. Image quality and LGE were qualitatively evaluated using a five-point Likert scale by two readers, and signal-to-noise ratio, contrast-to-noise ratio, and LGE mass were quantitatively assessed. Bland-Altman plots were used to evaluate interreader agreement. Results There was no evidence of a difference in the acquisition time for obtaining a single-layer PSIR image at 5.0 T compared with 3.0 T (<i>P</i> > .05 for all), irrespective of resolutions at 1.2, 0.9, and 1.6 mm. The 5.0-T PSIR images demonstrated better image quality and LGE visualization compared with 3.0-T images, particularly at 1.2 mm (image quality: median 5 [IQR, 5-5] vs median 5 [IQR, 4-5]; <i>P</i> = .004; LGE score: median 5 [IQR, 5-5] vs median 4.25 [IQR, 4-5]; <i>P</i> < .001). No evidence of differences in image quality or LGE scores was found between 5.0-T and 3.0-T cardiac MRI at 1.6-mm resolution. Signal-to-noise ratio and contrast-to-noise ratio were higher on 5.0-T PSIR images across all resolutions compared with 3.0-T images (<i>P</i> < .001 for all), but no evidence of a difference was found in LGE mass measurements. Conclusion The study demonstrates that 5.0-T PSIR imaging offers better image quality and LGE visualization than 3.0-T PSIR, particularly at a 1.2-mm resolution, in individuals with nonischemic cardiomyopathy. <b>Keywords:</b> MRI, Cardiac, Heart, Comparative Studies, Nonischemic Cardiomyopathy, Late Gadolinium Enhancement, Phase-Sensitive Inversion Recovery <i>Supplemental material is available for this article.</i> ©RSNA, 2024.

Radiology Cardiothoracic ImagingVol. 6(6)
Shanghai Xuhui Central Hospital (CN)
Shanghai Shenkang Hospital Development Center
Openalex Percentile: Top 15%
Advanced MRI Techniques and Applications
1.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.