IONOMETRIC DETERMINATION OF FLUORIDE IONS IN WATER AND SOLUTIONS OF TABLE SALT USING ULTRASOUND

The use of ultrasound in the ionometric determination of fluoride ions in water and kitchen salt solutions with the use of preliminary ultrasound treatment of the solution was studied. Experimentally established optimal parameters of ultrasound - frequency 18-44 kHz, intensity ≥ 10 W/cm2 for a time ≥ 1 min. It is shown that pretreatment of the solution with ultrasound of the parameters found leads not only to the cleaning of the electrode from films of organic substances, but also to an increase in the magnitude of the analytical fluoride ions signal, an expansion of the linear region of the calibration graph from 10–5 to 3.5·10–7 M, a reduction response time of the electrode in solutions containing 10-5 M fluorine ions from 10-12 min to 2-3 min. It is shown that the found experimental facts can be explained by structural changes of solutions under the influence of ultrasound. A technique for determining the content of fluoride ions in common salt solutions and water has been developed. The detection limit of fluoride ions in water was 0.007 mg/l, in table salt – 1.2·10–5%.

Authors

Publication Details

Journal
Metrology and instruments
Published
2024-12-13
DOI
https://doi.org/10.30837/2663-9564.2024.2.06
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IONOMETRIC DETERMINATION OF FLUORIDE IONS IN WATER AND SOLUTIONS OF TABLE SALT USING ULTRASOUND

Oleg Ivanovych Yurchenko, Larisa Vladimirovna Baklanova, Олександр М. Бакланов, Тетяна В. Черножук et al.
Metrology and instruments
Analytical Chemistry and Sensors
article

IONOMETRIC DETERMINATION OF FLUORIDE IONS IN WATER AND SOLUTIONS OF TABLE SALT USING ULTRASOUND

Oleg Ivanovych Yurchenko, Larisa Vladimirovna Baklanova, Олександр М. Бакланов, Тетяна В. Черножук, I.T. Shevchenko
article en

Abstract

The use of ultrasound in the ionometric determination of fluoride ions in water and kitchen salt solutions with the use of preliminary ultrasound treatment of the solution was studied. Experimentally established optimal parameters of ultrasound - frequency 18-44 kHz, intensity ≥ 10 W/cm2 for a time ≥ 1 min. It is shown that pretreatment of the solution with ultrasound of the parameters found leads not only to the cleaning of the electrode from films of organic substances, but also to an increase in the magnitude of the analytical fluoride ions signal, an expansion of the linear region of the calibration graph from 10–5 to 3.5·10–7 M, a reduction response time of the electrode in solutions containing 10-5 M fluorine ions from 10-12 min to 2-3 min. It is shown that the found experimental facts can be explained by structural changes of solutions under the influence of ultrasound. A technique for determining the content of fluoride ions in common salt solutions and water has been developed. The detection limit of fluoride ions in water was 0.007 mg/l, in table salt – 1.2·10–5%.

Metrology and instruments(2)
Clean water and sanitation
Openalex Percentile: Top 75%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.