Performance of Silicon Carbide (SiC) ceramic based total hip arthroplasty, numerical resolution of tensile stresses

This study proposes a novel Ti/SiC metal matrix composite as a potential replacement for traditional metal-on-metal total hip arthroplasty. The primary objective is to address the significant issue of wear, metal debris, and degradation associated with metal-on-metal friction couples. To optimize the composite's mechanical properties, a micromechanical modeling approach was employed. Representative volume elements (RVEs) with various configurations (square, diamond, four fibers, and random) were analyzed to identify the most stress-resistant model. Subsequent finite element analysis was conducted to investigate the influence of different SiC volume fractions (40%, 50%, and 60%) on the stress distribution within the composite. The results indicate that the four-fiber model with a 40% SiC volume fraction exhibits the lowest von Mises stress (8.60 MPa). This finding suggests that this configuration offers the best compromise between mechanical strength and potential for improved biocompatibility, making it a promising candidate for biomechanical joint prosthesis applications.

Authors

Publication Details

Journal
STUDIES IN ENGINEERING AND EXACT SCIENCES
Published
2024-12-12
DOI
https://doi.org/10.54021/seesv5n2-768
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of Silicon Carbide (SiC) ceramic based total hip arthroplasty, numerical resolution of tensile stresses

Hacene Ameddah, Hammoudi Mazouz, Harroug Mohammed Ridha
STUDIES IN ENGINEERING AND EXACT SCIENCES
Orthopaedic implants and arthroplasty
article

Performance of Silicon Carbide (SiC) ceramic based total hip arthroplasty, numerical resolution of tensile stresses

Hacene Ameddah, Hammoudi Mazouz, Harroug Mohammed Ridha
article en

Abstract

This study proposes a novel Ti/SiC metal matrix composite as a potential replacement for traditional metal-on-metal total hip arthroplasty. The primary objective is to address the significant issue of wear, metal debris, and degradation associated with metal-on-metal friction couples. To optimize the composite's mechanical properties, a micromechanical modeling approach was employed. Representative volume elements (RVEs) with various configurations (square, diamond, four fibers, and random) were analyzed to identify the most stress-resistant model. Subsequent finite element analysis was conducted to investigate the influence of different SiC volume fractions (40%, 50%, and 60%) on the stress distribution within the composite. The results indicate that the four-fiber model with a 40% SiC volume fraction exhibits the lowest von Mises stress (8.60 MPa). This finding suggests that this configuration offers the best compromise between mechanical strength and potential for improved biocompatibility, making it a promising candidate for biomechanical joint prosthesis applications.

STUDIES IN ENGINEERING AND EXACT SCIENCESVol. 5(2)
Openalex Percentile: Top 56%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.