Exposure to Waste Anesthetic Gases Throughout Surgical Interventions: A Case Study in a Portuguese Local Health Unit

The accumulation of anesthetic gas residues in surgery units can pose health risks to healthcare professionals, highlighting the need to establish effective protection measures. This study evaluated waste anesthetic gas levels in a local health unit in northern Portugal to identify high-exposure areas during surgeries using general anesthesia. Measurements of desflurane, sevoflurane, carbon dioxide, air temperature, and relative humidity were taken during 20 surgeries carried out over approximately six months. The results showed that the thermal conditions were not adequately controlled, particularly the relative humidity levels. The detected WAG concentrations fluctuated across different locations, with concerning peaks being detected in specific settings. Desflurane levels reached 8.79 ppm in the general surgery room (GSR) and averaged 3.13 ppm in the recovery room (RR), while the sevoflurane levels averaged 2.06 ppm in the RR. High concentrations exceeding the recommendations of the U.S. National Institute for Occupational Safety and Health (NIOSH) were notably observed after endotracheal tube removal. In short surgeries, anesthetic gas levels exceeded safety limits, while long surgeries caused peaks in sevoflurane levels. Longer surgeries and higher occupancy were significantly linked to increased levels of WAG and carbon dioxide, emphasizing the need to improve ventilation and environmental controls to safeguard healthcare professionals.

Authors

Institutions

Publication Details

Journal
Atmosphere
Published
2024-12-19
DOI
https://doi.org/10.3390/atmos15121521
Primary Topic
Anesthesia and Neurotoxicity Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exposure to Waste Anesthetic Gases Throughout Surgical Interventions: A Case Study in a Portuguese Local Health Unit

Maria de Fátima Domingues, Joseane Débora Peruço Theodoro, Isabel Fernandes, Ermelinda Pereira et al.
Atmosphere
Anesthesia and Neurotoxicity Research
article

Exposure to Waste Anesthetic Gases Throughout Surgical Interventions: A Case Study in a Portuguese Local Health Unit

Maria de Fátima Domingues, Joseane Débora Peruço Theodoro, Isabel Fernandes, Ermelinda Pereira, Manuel Feliciano, Leonardo Martins Leal, Marta Fonseca Gabriel, Vanessa Yamanaka
article en

Abstract

The accumulation of anesthetic gas residues in surgery units can pose health risks to healthcare professionals, highlighting the need to establish effective protection measures. This study evaluated waste anesthetic gas levels in a local health unit in northern Portugal to identify high-exposure areas during surgeries using general anesthesia. Measurements of desflurane, sevoflurane, carbon dioxide, air temperature, and relative humidity were taken during 20 surgeries carried out over approximately six months. The results showed that the thermal conditions were not adequately controlled, particularly the relative humidity levels. The detected WAG concentrations fluctuated across different locations, with concerning peaks being detected in specific settings. Desflurane levels reached 8.79 ppm in the general surgery room (GSR) and averaged 3.13 ppm in the recovery room (RR), while the sevoflurane levels averaged 2.06 ppm in the RR. High concentrations exceeding the recommendations of the U.S. National Institute for Occupational Safety and Health (NIOSH) were notably observed after endotracheal tube removal. In short surgeries, anesthetic gas levels exceeded safety limits, while long surgeries caused peaks in sevoflurane levels. Longer surgeries and higher occupancy were significantly linked to increased levels of WAG and carbon dioxide, emphasizing the need to improve ventilation and environmental controls to safeguard healthcare professionals.

AtmosphereVol. 15(12)
Universidade Estadual de Londrina (BR), Universidade Tecnológica Federal do Paraná (BR), Universidade Politécnica de Bragança (PT), Institute of Mechanical Engineering and Industrial Mangement (PT), Unidade Hospitalar de Bragança (PT)
Kansainvälisen Liikkuvuuden ja Yhteistyön Keskus, Ministério da Ciência, Tecnologia e Ensino Superior, Fundação para a Ciência e a Tecnologia
Openalex Percentile: Top 73%
Anesthesia and Neurotoxicity Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.