Eye tracker calibration: How well can humans refixate a target?
Irrespective of the precision, the inaccuracy of a pupil-based eye tracker is about 0.5 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mmultiscripts><mml:mrow></mml:mrow> <mml:mrow></mml:mrow> <mml:mo>∘</mml:mo></mml:mmultiscripts> </mml:math> . This paper delves into two factors that potentially increase the inaccuracy of the gaze signal, namely, 1) Pupil-size changes and the pupil-size artefact (PSA) and 2) the putative inability of experienced individuals to precisely refixate a visual target. Experiment 1 utilizes a traditional pupil-CR eye tracker, while Experiment 2 employs a retinal eye tracker, the FreezeEye tracker, eliminating the pupil-based estimation. Results reveal that the PSA significantly affects gaze accuracy, introducing up to 0.5 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mmultiscripts><mml:mrow></mml:mrow> <mml:mrow></mml:mrow> <mml:mo>∘</mml:mo></mml:mmultiscripts> </mml:math> inaccuracies during calibration and validation. Corrections based on the relation between pupil size and apparent gaze shift substantially reduce inaccuracies, underscoring the PSA's influence on eye-tracking quality. Conversely, Experiment 2 demonstrates humans' precise refixation abilities, suggesting that the accuracy of the gaze signal is not limited by human refixation inconsistencies.
Authors
- Diederick C. Niehorster (ORCID: https://orcid.org/0000-0002-4672-8756)
- Anna Szkulmowska
- Ignace T. C. Hooge (ORCID: https://orcid.org/0000-0002-2790-892X)
- Patrycjusz Stremplewski (ORCID: https://orcid.org/0000-0002-4743-4397)
- Roy S. Hessels (ORCID: https://orcid.org/0000-0002-4907-1067)
- Robert Konklewski
- Maciej Szkulmowski (ORCID: https://orcid.org/0000-0002-2006-0524)
- Marcus Nyström (ORCID: https://orcid.org/0000-0002-2089-9012)
- Richard Andersson (ORCID: https://orcid.org/0000-0001-7971-0870)
- Marta K. Skrok (ORCID: https://orcid.org/0000-0002-2768-9595)
- Szymon Tamborski (ORCID: https://orcid.org/0000-0002-3636-5824)
- Maciej Nowakowski (ORCID: https://orcid.org/0000-0003-0583-121X)
Institutions
- Lund University (SE)
- Utrecht University (NL)
- Nicolaus Copernicus University (PL)
- Institute of Physics (PL)
- Tobii (Sweden) (SE)
Publication Details
- Journal
- Behavior Research Methods
- Published
- 2024-12-19
- DOI
- https://doi.org/10.3758/s13428-024-02564-4
- Citations
- 14
- Primary Topic
- Gaze Tracking and Assistive Technology
- Type
- article
- Field-Weighted Citation Impact
- 5.21
Funders
- Lunds Universitet
- Uniwersytet Mikolaja Kopernika w Toruniu