Fluctuating high-frequency variability index in a patient implanted with pacemaker: A case report

High-frequency variability index, which is calculated based on heart rate variability derived from the R-wave peak to R-wave peak interval in the electrocardiogram, is used in clinical settings to adjust intraoperative opioid administration. Theoretically, patients implanted pacemaker with fixed rate have no fluctuation in high-frequency variability index due to constant R-wave peak to R-wave peak interval. We experienced a case with fluctuating high-frequency variability index in a patient implanted with pacemaker. A 75-year-old female implanted with a cardiac pacemaker owing to a complete atrioventricular block, underwent total knee arthroplasty. In the operating room, the pacemaker rate was set to 70 bpm in VOO mode and her surgery was started. Unexpectedly, the high-frequency variability index fluctuated between 35 and 80 during her surgery. While the exact reasons for these fluctuations are unclear, electrical impulses generated by the pacemaker and transmitted via electrodes to the myocardium may induce myocardial contractions, contributing to the observed variations in high-frequency variability index. Thus, it is crucial to note that a fluctuating high-frequency variability index in patients with implanted cardiac pacemakers does not reliably reflect their autonomic tone.

Authors

Institutions

Publication Details

Journal
JCA advances.
Published
2024-12-19
DOI
https://doi.org/10.1016/j.jcadva.2024.100084
Citations
1
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fluctuating high-frequency variability index in a patient implanted with pacemaker: A case report

Masahiko Kawaguchi, Nobuhiro Tanaka, Ken Hattori, Mitsuru Ida
1 citations
JCA advances.
Cardiac pacing and defibrillation studies
0.40
article

Fluctuating high-frequency variability index in a patient implanted with pacemaker: A case report

Masahiko Kawaguchi, Nobuhiro Tanaka, Ken Hattori, Mitsuru Ida
article en
1 citations

Abstract

High-frequency variability index, which is calculated based on heart rate variability derived from the R-wave peak to R-wave peak interval in the electrocardiogram, is used in clinical settings to adjust intraoperative opioid administration. Theoretically, patients implanted pacemaker with fixed rate have no fluctuation in high-frequency variability index due to constant R-wave peak to R-wave peak interval. We experienced a case with fluctuating high-frequency variability index in a patient implanted with pacemaker. A 75-year-old female implanted with a cardiac pacemaker owing to a complete atrioventricular block, underwent total knee arthroplasty. In the operating room, the pacemaker rate was set to 70 bpm in VOO mode and her surgery was started. Unexpectedly, the high-frequency variability index fluctuated between 35 and 80 during her surgery. While the exact reasons for these fluctuations are unclear, electrical impulses generated by the pacemaker and transmitted via electrodes to the myocardium may induce myocardial contractions, contributing to the observed variations in high-frequency variability index. Thus, it is crucial to note that a fluctuating high-frequency variability index in patients with implanted cardiac pacemakers does not reliably reflect their autonomic tone.

JCA advances.Vol. 2(1)
Nara Medical University Hospital (JP), Nara Medical University (JP)
Openalex Percentile: Top 29%
Cardiac pacing and defibrillation studies
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fluctuating high-frequency variability index in a patient implanted with pacemaker: A case report — Masahiko Kawaguchi, Nobuhiro Tanaka, et al. · JCA advances. (2024) | TGRS Research Map | TGRS