Uncomplicated Extravascular Implantable Cardioverter‐Defibrillator Extraction After 4 Years Dwell Time: A Case Report

The extravascular implantable cardioverter-defibrillator (EV-ICD) was developed to overcome complications associated with transvenous leads while being able to deliver anti-tachycardia pacing (ATP). The lead is implanted in the substernal space, which makes extraction a cautious procedure. We present a case of a 51-year-old women with a successful EV-ICD extraction after a lead dwell time of 4 years, which is the longest reported. The EV-ICD lead was extracted using simple traction after the removal of all adhesions at the xiphoidal site around the lead. We advise to only use extraction tools if the initial attempt is not successful and if no adhesions at the caudal part of the lead are visible anymore, as these tools could also damage the surrounding tissue and the lead.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Electrophysiology
Published
2024-12-18
DOI
https://doi.org/10.1111/jce.16530
Citations
7
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
2.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncomplicated Extravascular Implantable Cardioverter‐Defibrillator Extraction After 4 Years Dwell Time: A Case Report

Kirsten M. Kooiman, Jolien A. de Veld, Reinoud E. Knops
7 citations
Journal of Cardiovascular Electrophysiology
Cardiac pacing and defibrillation studies
2.81
article

Uncomplicated Extravascular Implantable Cardioverter‐Defibrillator Extraction After 4 Years Dwell Time: A Case Report

Kirsten M. Kooiman, Jolien A. de Veld, Reinoud E. Knops
article en
7 citations

Abstract

The extravascular implantable cardioverter-defibrillator (EV-ICD) was developed to overcome complications associated with transvenous leads while being able to deliver anti-tachycardia pacing (ATP). The lead is implanted in the substernal space, which makes extraction a cautious procedure. We present a case of a 51-year-old women with a successful EV-ICD extraction after a lead dwell time of 4 years, which is the longest reported. The EV-ICD lead was extracted using simple traction after the removal of all adhesions at the xiphoidal site around the lead. We advise to only use extraction tools if the initial attempt is not successful and if no adhesions at the caudal part of the lead are visible anymore, as these tools could also damage the surrounding tissue and the lead.

Journal of Cardiovascular ElectrophysiologyVol. 36(1)
Amsterdam University Medical Centers (NL)
Good health and well-being
Openalex Percentile: Top 8%
Cardiac pacing and defibrillation studies
2.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.