A Study on the Insulation Performance Analysis of Liquid Hydrogen Storage Tank with 66-layer Multi-layer Insulation

The purpose of this study is to evaluate a vacuum composite insulation system for liquefied hydrogen tank application by building a structural unit insulation performance evaluation equipment and conducting experimental research on boil-off gas generation inside the tank. As a cornerstone study for future experimental research on MLI of high vacuum insulation system, the insulation performance is evaluated according to the heat flow rate, effective thermal conductivity, and boil-off rate derived from the experimental results. In particular, in the case of MLI, it is important to secure experimental data reliability of structural unit insulation performance because the material performance of standard materials and laboratory units may differ from that of structural units. Therefore, as a cornerstone study to secure experimental data reliability, this study developed a structural unit testbed in the form of a double tank capable of cryogenic cargo transportation, and obtained and analyzed insulation performance results in a soft vacuum.

Authors

Publication Details

Journal
Journal of the Society of Naval Architects of Korea
Published
2024-12-19
DOI
https://doi.org/10.3744/snak.2024.61.6.490
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study on the Insulation Performance Analysis of Liquid Hydrogen Storage Tank with 66-layer Multi-layer Insulation

Byeong-Kwan Hwang, G.M. Lee, Hee-Tae Kim, Jeong‐Hyeon Kim et al.
Journal of the Society of Naval Architects of Korea
Engineering Applied Research
article

A Study on the Insulation Performance Analysis of Liquid Hydrogen Storage Tank with 66-layer Multi-layer Insulation

Byeong-Kwan Hwang, G.M. Lee, Hee-Tae Kim, Jeong‐Hyeon Kim, Seung-Joo Cha, Jong‐Pil Lee, Jae‐Myung Lee
article en

Abstract

The purpose of this study is to evaluate a vacuum composite insulation system for liquefied hydrogen tank application by building a structural unit insulation performance evaluation equipment and conducting experimental research on boil-off gas generation inside the tank. As a cornerstone study for future experimental research on MLI of high vacuum insulation system, the insulation performance is evaluated according to the heat flow rate, effective thermal conductivity, and boil-off rate derived from the experimental results. In particular, in the case of MLI, it is important to secure experimental data reliability of structural unit insulation performance because the material performance of standard materials and laboratory units may differ from that of structural units. Therefore, as a cornerstone study to secure experimental data reliability, this study developed a structural unit testbed in the form of a double tank capable of cryogenic cargo transportation, and obtained and analyzed insulation performance results in a soft vacuum.

Journal of the Society of Naval Architects of KoreaVol. 61(6)
Affordable and clean energy
Openalex Percentile: Top 73%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Study on the Insulation Performance Analysis of Liquid Hydrogen Storage Tank with 66-layer Multi-layer Insulation — Byeong-Kwan Hwang, G.M. Lee, et al. · Journal of the Society of Naval Architects of Korea (2024) | TGRS Research Map | TGRS